Recommended minimum conductor cross-section and maximum power-cord length for 120V supply
voltage
Cord
Conductor cross-section
Conductor cross-section
Cord length
Cord length
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1
Fitting the side handle
CAUTION
Risk of injury! Loss of control over the breaker.
▶ Check that the side handle is fitted correctly and tightened securely.
1. Slide the side handle clamping band over the chuck from the front and into the recess provided.
2. Bring the side handle into the desired position.
3. Secure the side handle by turning the knob until the clamping band is tight.
5.1.2
Fitting the accessory tool
WARNING
Risk of injury! The tool becomes hot as a result of use.
▶ Wear protective gloves when changing the tool.
1. Apply a little grease to the connection end of the accessory tool.
2. Push the accessory tool into the chuck as far as it will go (until it engages).
◁ The product is ready for use.
5.1.3
Positioning the chisel
CAUTION
Risk of injury! Loss of control over the chisel direction.
▶ Do not operate the tool when the selector switch is set to "Chisel positioning". Turn the function selector
switch until it engages in the "Chiseling" position.
The chisel can be adjusted to 24 different positions (in 15° increments). This ensures that flat chisels
and shaped chisels can always be set to the optimum working position.
1. Set the function selector switch to the
2. Rotate the chisel to the desired position.
3. Engage the function selector switch in the
◁ The tool is ready for use.
5.1.4
Removing the accessory tool
DANGER
Risk of fire! Risk of contact between the hot accessory tool and highly inflammable materials.
▶ Do not lay the hot accessory tool down on highly inflammable materials.
6
English
Printed: 18.04.2018 | Doc-Nr: PUB / 5071000 / 000 / 05
AWG 16
1,31 mm²
2,58 kcmil
25 m
75 ft
2
3
4
position.
position.
5
AWG 14
AWG 12
2,08 mm²
3,31 mm²
4,11 kcmil
6,53 kcmil
30 m
50 m
100 ft
150 ft
378617
AWG 10
5,26 mm²
10,4 kcmil
100 m
250 ft
*378617*