Range
Measuring Accuracy
Resolution
Laser Class
Laser Wavelength
Auto Power Switch Off
Battery Life
Dimensions (H x D x W)
Weight (with Batteries)
Storage Temperature Range
Operating Temperature Range
* Under favorable conditions (good target surface, room temperature) up to 33 ft (10m). Under unfavorable
conditions, such as bright sunlight, a very weak reflecting target surface or large temperature fluctuations,
the error can increase by ± 0.003 in/ft. (± 0.25 mm/m) for distances over 33 ft. (10m).
ERROR
DESCRIPTION
CODE
Received signal too weak/
101
measuring time too long.
102
Received signal too high.
201
Too much background light.
202
Laser beam interrupted.
203
Insufficient battery.
301
Temperature too high.
302
Temperature too low.
401
Hardware error.
402
Unknown error.
If the troubleshooting section does not resolve or describe your problem, contact Uline Customer Service at
1-800-295-5510.
PAGE 5 OF 15
SPECIFICATIONS
4" to 100' (0.1m to 30m)
Typ.:±2.0mm*/±0.12mm
1/16" (1mm)
2
620-690nm, Power < 1 mW
After 3 minutes
Up to 3,000 measurements ( 2,500 with Bluetooth* )
4.86 x 2.28 x 1.10" (119 x 58 x 28mm)
3.231 oz. (100g)
-13 to 158º F (-25 to 70ºC )
-32 to 104º F (-0 to 40ºC )
TROUBLESHOOTING
Use target plate or change target surface.
Target too reflective. Use target plate or change target surface.
Reduce background light on target area.
Remove obstacle and repeat measurement.
Replace batteries.
Allow device to cool to operating temperature.
Allow device to warm up to operating temperature.
Switch on/off device several times.
Contact Uline Customer Service.
1-800-295-5510
uline.com
CORRECTIVE ACTION