Range
Measuring Accuracy*
Resolution**
Laser Class
Laser Type
Laser/Backlight Automatic Switch Off
Auto Power Switch Off
Continuous Measuring
Area/Volume
Battery Life
Dimensions (H x D x W)
Weight (with Batteries)
Storage Temperature Range
Operating Temperature Range
* Under favorable conditions (good target surface, room temperature) up to 33 ft (10m). Under unfavorable
conditions, such as bright sunlight, a very weak reflecting target surface or large temperature fluctuations,
the error can increase by ± 0.003 in/ft. (± 0.25 mm/m) for distances over 33 ft. (10m).
** Resolution is the finest measurement you can see. In inches, that is 1/16". In millimeters, that is 1 mm.
NOTE: If "INFO" appears on the display window with a code number, perform the
corresponding corrective action.
ERROR
CODE
Received signal too weak/
101
measuring time too long.
102
Received signal too high.
201
Too much background light.
202
Laser beam interrupted.
PAGE 5 OF 18
SPECIFICATIONS
TROUBLESHOOTING
DESCRIPTION
4" to 100' (0.1 m to 30 m)
± 3/32" (± 2 mm)*
1/16" (1 mm)**
2 (IEC/EN 60825-1 : 2014)
≤
620-690 nm, Power
1 mW
After 30 seconds
After 90 seconds
Yes
Yes
Up to 3,000 measurements ( 2,500 with Bluetooth )
4.72 x 1.91 x 1.02" (120 x 48.5 x 26 mm)
3.21 oz. (100 g)
14 to 140ºF (-10 to 60ºC )
32 to 104ºF (0 to 40ºC )
CORRECTIVE ACTION
Use target plate or change target surface.
Target too reflective. Use target plate or change target
surface.
Reduce background light on target area.
Remove obstacle and repeat measurement.
0720 IH-8816