EN
Important & Functions
READ THIS FIRST!
IMPORTANT!
Please read these instructions carefully
before use. The fan is designed for per-
manent installation and must be instal-
led by an authorized electrician.
According to the EN 60335 Standard, the
following must be taken into account:
This product can be used by persons
aged 8 years and over and by persons
with reduced physical or mental ability
or lack of experience and knowledge,
if they have received guidance or been
instructed on the use of the product
in a safe manner and are aware of the
risks. Children must not play with the
product. Cleaning and maintenance
must not be carried out by children
without supervision. The fan channel
length must not be less than 200mm.
When mounting in wall or ceiling the
external opening must always be
protected against rain/snow with a
hood/exterior grille.
6
FUNCTIONS
Automatic humidity control system
Fully automatic humidity control, which means the fan
increases the air flow at increased humidity. The air flow
can be adjusted from the control panel or via the app.
Air quality sensor
The fan is also equipped with an air quality sensor
that increases the air flow when the air is poor.
The air flow is the same as that selected for automatic
humidity control system.
Timer
Triggered via light sensor or igniter wire. Possibility of
a 2 minute delay, and selectable run-on time 15 or 30
minutes. The air flow can be adjusted from the control
panel or via the app.
Continuous operation
Let the fan run continuously if you need basic ventila-
tion in your home. The flow can be adjusted from the
control panel or via the app.
Airing function
If the fan has been inactive for 26 hours, it will run an
airing program for 60 minutes.
The airing function is not active when the fan in run-
ning continuously. The air flow can be adjusted from
the control panel or via the app.
App
The Fresh ventilation app can be downloaded to
Android and IOS phones. The app gives you access to
a variety of settings and functions.
See the Fresh website for detailed information on all
fan functions with and without the app. www.fresh.eu
fresh ventilation
APP
Technical data & Dimensional drawing & Reset
Technical data
Maximum airflow (free blowing)
140 m³/h
Min sound pressure level
19 dB (A) 3 m
Max pressure
57 Pa
Power consumption
2 - 5 W
Spigot depth
29 mm
Hole size
105 - 130 mm
Material
ABS plastic
Protection rating
IP44
Insulation class
X
Voltage Frequency
100 - 240V AC 50 - 60 Hz
Certificates
DC6
Mounting options
Wall or ceiling
Bluetooth LE
-12dBm EIRP (63µW), nominal 2450MHz
Speed
Timer
Function
Humidity
control
Continuous
Light
Air quality
sensor
Reset
Press the function button once. Press and hold
the function button for at least 5 seconds.
Ø98
Ø118
185
Settings
Press the function icon and all adjustable/programmable
symbols will light up. Then press any of the Timer, Humidity
control, Continuous or Light/Air quality symbols.
This will only light up the selected function, which is then
ready for adjustment. Possibility to control speed/flow
+/- is provided for certain functions. Lit lamps next to each
symbol indicate the function selection.
See the Fresh website for detailed information on all fan
functions with and without the app. www.fresh.se
Factory settings
On delivery, Intellivent ICE has the following functions:
Continuous operation
approx 10 l/s*
Airing function
1 hour/day
Timer
approx 20 l/s* 15 minutes
Automatic humidity control
approx 28 l/s*
* freeblowing
7