CARE AND MAINTENANCE

WARNING: Always disconnect pump from power source before
handling.
At least every three months inspect and test operation:
1.. Check to be sure green 'system ready' light is on (indicates
AC power is on and there are no alarm conditions)
2. Test for operation:
A. Unplug primary pump and controller.
Fill basin with water to the 'on' level of the backup pump
and allow the pump to run for several minutes.
NOTE: The alarm will sound approximately one second
after the pump starts to run.
B. Push the Silence/reset button - the alarm will shut off.
The pump will shut off after the water level is lowered
and the float drops to the 'off' position.
Hold the Silence/reset button for three seconds to reset
the controller and clear any alarms or indicators
C. Plug the controller and the primary pump into the 115V
outlets. The primary pump will turn on and then off when
water reaches normal level.
The pump will continue to run after the float is lowered
or until the controller senses water is being pumping.
The four circle lights will be blue. The battery light will
flash slowly after the test as it recharges the battery. The
lights will turn green once the battery is recharged.
19
© 2020. All rights reserved.
2A
2C
1
by
AC
FLOAT
POWER
STATUS
TEST
24/7 BASEMENT
PROTECTION
DC
BATTERY
PUMP
SILENCE
USB
1-800-584-8089
DC POWER
DC
FUSE
+ 15V DC 1.6A
BasementSentry.com
RESET
FLOAT
PUMP
30 AMP
2B
2A

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido