uSED SyMBOLS/ TEChNICaL DaTa/ NOTE
Fitting items
Tools/ Montage
Dimensions Diagramm
hnical Data
Tec
Caution water!
Before drilling the bottom hole pay
attention if water supply pipes cross
this area.
Minimum flow pressure
Operating pressure
Recommended operating pressure
Test pressure
(1 MPa = 10 bar = 147 PSI
Hot water temperature
Safety stop
Flow capacity at 0,3 MPa
Headshower
Handshower
Body showers 3 Stück
Head- + Bodyshowers
Dimensions
The installation dimensions stated in this installation instructions
are ideal for people of approximately 1800 mm in body height.
The dimensions can be altered if required. In this case you will
have to attend to the minimum height of 2250 mm from shower
tray floor, and alter all the required measurements as necessary.
If the height of water connection are outside of the illustrated
range, the drill measurements must be adjusted accordingly.
(attention for minimum room height of 2250 mm from tub-floor).
Flush through the supply pipes(DIN EN 1717).
6
1.
0,3 MPa
Operation, spare parts and flow capacity diagramm see on
page 2 + 3.
0,3- 1,0 MPa
Spare part numbers with XXX identification must be replaced
0,3- 0,5 MPa
by the code number relating to the finish of the product.
000
1,6 MPa
Spare part numbers with *- identification are option.
• identification in flow diagram:
From • the function is guaranteed.
max. 70° C
38° C
Operation and function from handshower see on
enclosed brochure.
7,8 l/min
10,2 l/min
7,8 l/min
11,5 l/min
Note
Informs the personnel concerned of
information with important contents to
be observed.
water connection DN 15
hot water 1/2"
water connection DN 15
cold water 1/2"
Montage
chrom
use only free from acetic acid
Flow heater
Applicable for flow heaters at min. 24 kW and 0.3 MPa
flow pressure before the Shower panel and a mini-
mum through flow of 7 l/minute. Only one consumer
possible, not two simultaneously.
Pressure differences
The pressures of the cold and hot water connections
must be balanced.