Operation
PENTEK Pressure Central
Input to Control
Volts/Hz/Phase:
PPC20-1A-6A8-4
PPC20-1A-6A0-4
Maximum RMS Current
Circuit Breaker Rating
Internal Fusing:
PPC20-1A-6A8-4
PPC20-1A-6A0-4
Output Power to Motor
PPC20-1A-6A8-4
PPC20-1A-6A0-4
Frequency
Max. Length of Wire, Control to Motor
14 AWG
12 AWG
Pressure Setting
Control is Factory Preset to
Adjustable Range
Tank Precharge
Ambient Conditions
Operating Temperature Range, PPC20-1A-6A8-4
Operating Temperature Range, PPC20-1A-6A0-4
Storage Temperature Range
Humidity Range
Auxiliary Relay Rating:
Dimensions:
Weight:
Enclosure:
Internal Overload Protection:
Constant Pressure Control Specifications
TM
(42 psi pre-charge for factory-set 60 psi set point)
Trips at 8.5 Amps (125% of Maximum Power Output)
230V/50-60Hz/1ø
115V/50-60Hz/1ø
BAF-15 (250 volts, 15 amps)
BAF-30 (250 volts, 30 amps)
Up to 2.0 BHP, 230V, 6.8A, 3ø Output
Up to 1.4 BHP, 230V, 6.0A, 3ø Output
Variable: 30-60, 30-80 or 30-200 Hz
70% of Pressure Set point
-4° F to 131° F (-20° C to 55° C)
-4° F to 104° F (-20° C to 40° C)
-40° F to 185° F (-40° C to 85° C)
250 Volts, 16 Amps
13-3/8" H x 10-7/8" W x 5-7/8" D
NEMA4, IPX4, radiant cooled
16 Amps
20 Amps
300'
400'
60 psi
25-95 psi
10% to 90%
20 lbs.
7