INSTALLATION
Warning!
Do not install on any flammable material.
Do not cover the heater.
Only connect to a 220-240VAC power supply.
The unit must be earthed.
When ceiling mounted, the distance between the heater and the ceiling must be more than 60mm.
No objects within 500mm below the heater.
Accessories
1. Bracket welded with M5 nut for the unit x 2
2. Bracket for the wall x 2
3. Butterfly screw x 8
4. Butterfly nut x 4
5. Expansion screw x 4
a.
Flat washer
b.
Spring washer
c.
Nut
d.
Threaded rod
Installation steps
1. Insert the two brackets welded with M5 nut into the grooves on the rear cover of the unit, from the left side
(the side without the control box). Move the brackets to your desired position and tighten with the butterfly
screws. See picture .
(Make sure the two brackets are fixed firmly in a balanced position when the unit is hung up.)
Note: The brackets are welded with the M5 nuts. You can tighten the butterfly screws directly through the
nuts (without holes on the unit).
2. Install the rest two brackets to the ceiling or the side wall.
-
Measure the distance between the two brackets on the unit. Measure the distance between the two
holes (Approximately 8.5cm) on the bracket for the wall. Drill four holes (Diameter: 6mm; depth: 60mm)
on the wall according to below chart.
- 50 -