Note for installation in connection with extensions:
If you would like to install the door gate in connection with extensions, please start on page 11
and follow the instructions "Installation of Extensions".
ATTENTION: The gate must always open in the direction away from the hazard zone!
Installation
In order to limit the opening direction, installation of the stopper (j) Ill. 1 is optional.
Step 1
Insert the 4 screw housings (a, c, d) together with the adjusting screws (e) and (f) into the 4
corners of the gate. Please follow the instructions of Ill. 2 - 5 exactly when inserting the parts
(a, c, d).
Push the screw housings (c) only slightly in, so that the colours remain visible, Ill. 4.
Push the screw housings (a) and (d) in completely, Ill. 2, Ill. 3, Ill. 5.
Attention! The screw housings (a, c, d) do not have an inside thread. The screws are merely
pushed in or pulled out.
Step 2
Place the safety gate on the floor and make sure the gate stands upright in the middle of the
doorway so that there is no more than 62mm between the safety gate and the door frame. Ill. 6.
Pull the lower adjusting screws out evenly until they touch the mounting areas, Ill 7 and 8.
Mounting the wall shells (g)
When is the screw connection of the wall shells (g) absolutely necessary?
ATTENTION!
When is the screw
• On a wooden surface -> with the included wood screws (h)
connection of the
• On plaster or soft surfaces -> with suitable screws and wall anchors 1)
wall shells
Remove the protective foil on the adhesive surface on the back of the wall shells and place these
necessary?
between the adjustment screws and the mounting surface, Ill. 09 and 10.
Tip: Make the mounting easier by only turning back the adjustment screw slightly on one side of
the door gate whilst the opposite adjustment screws of the gate provide support on the mounting
surface.
adjusting the lower
Using the key tighten the nuts on the lower part evenly until the screw housing (c) is pressed into the
adjustment screws
frame so that only the green stripe is visible, Ill. 11.
ATTENTION! If in spite of installation of the wall shells the green colour in the colour indicator does
not appear, the surface to which it is attached is not stable enough. If this is the case, a protection
guard must be used for the screw connection, or the clamping surface of the wall must be
reinforced, e.g. by using the StairFlex protection board.
- 10 -
1) not included in scope of delivery