Technical data:
• Measuring range: 0.05 m - 60 m
• Measuring accuracy (standard deviation): ± 2.0 mm (<10m)
• Units of measurement: m, ft, in
• Units of area: m², ft²
• Laser type: 620-690 nm
• Laser class: II (<1 mW)
• Measuring time for single measurement: 0.25 s
• Operating temperature: 0...+40°C
• Storage temperature: -20...+65°C
• Batteries: AAA (alkaline), 2x1.5 V
• Number of measurements per battery set: > 5000
• Weight (without batteries): 85 g
• Dimensions: 120 x 48 x 24 mm
A maximum deviation error or shorter range can occur when the laser is exposed to bright sunlight, operated over a very rough or minimally
reflective surface, or used under extreme temperature conditions.
For measurements within 10 m, the measuring accuracy is:
For measurements over 10 m, the measuring accuracy is calculated as follows: ± 2.0 + (0.05 x (D-10)) [mm] D = measuring distance in m
LCD description
LCD symbol display
LASER REFLECTION INTENSITY
AREA / VOLUME / HYPOTENUSE
LASER "ON"
REFERENCE
CONTINUOUS MEASUREMENT
CURRENT MEASUREMENT
MEMORY DATA READING
BATTERY STATUS
HARDWARE ERROR
UNIT
Key functions / symbols
Key functions
Switch on / measure distance
Select measurement function
Plus [+] / Minus [-]
Delete / switch off
References
Data management / measuring unit
± 2.0 [mm]
Symbol