DEBUG Mode
Debug mode allows you to identify which cable pairs
have a wiring fault. This mode cycles through each
cable pair, displaying a test result for one pair at a
time. From the series of LED indicators, the failed
pair and fault condition can be identified. In Debug
mode, the first short flash on the PAIR LEDs display
the pair under test. The second long flash on the
PAIR LEDs is the destination of the test.
To DEBUG:
1. Press and hold the "TEST" button unitl all cable
pairs have been tested.
2. The PAIR identification LEDs and the FAIL LEDs
work together in series to identify which pair(s)
are incorrectly wired.
3. If a series of two green LEDs (one short and one
long) display as a pair, then that pair is wired
correctly.
4. A green PAIR LED followed by a red LED in the
FAIL section reveals which pair is incorrectly wired
and the fault associated with that pair.
5. Debug mode continues to cycle through each
cable pair until the "TEST" button is released,
termintating the test.
01-155-9337F4.indb 7
7
2/20/2018 9:59:41 A