Technical Data - Grohe Contromix 36 109 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
GB
Application
Prod. no. 36 111:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of mixed water supply
Prod. no. 36 109 and 36 110:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical Data

• Flow pressure
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar,
fit a pressure-reducing valve.
• Flow rate at 3 bar flow pressure
• Infinitely variable running time from 5 - 40 s
(factory setting: 15 s)
Prod. no. 36 109 and 36 110:
• Temperature
Hot water inlet
• Water connection
Note
Avoid major pressure differences between hot and
cold water supply.
Installation
, see Figs. [1 - 3].
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Refer to the dimensional drawings on fold-out page I.
Failure
Fault
Fitting does not close
- flow is too low
- cartridge defective
- O-ring damaged
Fitting does not open
- service valve closed
- cartridge defective
Flowtime too short or too long
- wrong setting
- cartridge defective
Flow volume too small
- dirt strainers blocked
- service valve not fully open
- mousseur clogged with limescale
Hot water forced into cold water line
- non-return valve dirty or defective
Connection
Screw adapter together with seal onto the service valve.
In order to ensure permanent, trouble-free operation,
installation of the enclosed adapter with dirt strainer and
non-return valve is mandatory.
Open hot and cold water supply and check connections
for leakage.
Operation
, see Fig. [4].
Maintenance
Assemble in reverse order.
Setting
, see Figs. [12 - 16].
Setting the water flow time, see Figs. [12] and [13].
• Align toothed disc (A), see Fig. [12].
1.2 - 5 bar
• Attach pushbutton cap (B), ensuring that toothed disc (A) is
max. 10 bar
still free to turn.
16 bar
Adjustment of water flow time is infinitely variable
from 5 - 40 s (2.5 s for one complete rotation).
approx. 6 l/min.
Setting the desired maximum temperature, see Figs. [12]
and [14] to [16].
• Align toothed disc (A), see Fig. [12].
• Attach pushbutton cap (B) and set the desired maximum
temperature, see Fig. [14].
• Remove pushbutton cap (B).
max. 60 °C
• Mark toothed disc (A) level with left stop (C), see Fig. [15].
cold - right
• Realign toothed disc (A), see Fig. [16].
hot - left
Assemble in reverse order.
Replacement parts, see fold-out page I (* = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
• check
• replace cartridge and if necessary O-ring
• replace
• open
• replace cartridge and if necessary O-ring
• set flow time
• replace cartridge and if necessary O-ring
• clean
• open
• clean
• clean or replace
, see Figs. [5 - 11].
Figure
5 - 8
7
5 - 8
12 - 13
5 - 8
10 - 11
10 - 11
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Contromix 36 110Contromix 36 111

Tabla de contenido