TANK CLEANING
For cleaning operation of the tank proceed as follows:
1) Remove the product from the tank.
2) Switch off the unit using main switch (see control panel) and unplug the unit.
3) Before cleaning the tank the inside temperature must be the same as the ambient.
4) Clean the tank; don't use too much water that could damage the motor fans; rinse and dry carefully.
5) Turn the unit on, with the night curtain (if present) lowered and 1 hour later you can load the product again.
Warning! Do not use water jets for cleaning: this can damage the electrical
parts.
Warning! Do not use mechanical appliances or other means to speed up the
defrosting process, other than those recommended by the manufacturer.
APPLIANCES USING R404a COOLING FLUID
On theese appliances the defrosting is automatic.During the defrosting period, the resulting water
is collected into a stainless stell tray and dispelled by an automatic electrical evaporating system. In
case of fault the security thermostat breaks the voltage to the electrical resistance, and the water brims
on the floor; call the operator, who must reset the thermostat stud only after having eliminate the
cause of the fault.
SAFETY THERMOSTAT
RESET BUTTON
GEMMA 60
SAFETY THERMOSTAT
RESET BUTTON
Warning!
Check and clean periodically the tray sucking any dirt and/or remnants with a properly powerful
aspirator suitable for liquids.
AUTOMATIC DEFROSTING
GEMMA 120 - 180
GEMMA 30
-18-
SAFETY THERMOSTAT
RESET BUTTON
ATTENZIONE
ATTENTION
WARNING
IN CASO DI MANCATO FUNZIONAMENTO
DELLA RESISTENZA VERIFICARE E
RIPRISTINARE IL TERMOSTATO DI
SICUREZZA PREMENDO IL PULSANTE
SI LA RESISTANCE NE FUNCTION PAS
VERIFIER ET RETABLIR LE POUSSOIR
DU THERMOSTAT DE SECURITE
IF THE HEATER DON'T WORK PLEASE
VERIFY AND REPAIR THE SAFETY
THERMOSTAT SWITCH LAYING