11.1 ELECTRONIC CLUTCH
To adjust the anti-crushing system tripping threshold use trimmer "A". To reduce the torque, turn the trimmer counterclockwise.
To increase the torque, turn the trimmer clockwise. It is recommend to calibrate this torque to meet current standards.
11.2 PAUSE
To adjust the pause duration (for automatic operation), use trimmer "B". The duration can be adjusted from 6 to 120 seconds.
11.3 OPEN/CLOSE
To adjust the duration of the gate opening/closing time, use trimmer "C". The duration can be adjusted from 0 to 60 seconds.
Note: To obtain maximum system efficiency, adjust the opening/closing time so that the electric motor can be fed for a few
seconds after the section has reached the mechanical stop.
11.4 TIMING
If the movement of the sections must be timed differently to ensure that the gate opens and closes correctly, it is possible to
delay the movement of the sections. To carry out such an adjustment, use trimmer "D". For opening, delay of the section
driven by motor 2: trimmer at a minimum 0 secs.; trimmer in any other position 2 seconds fixed. For closing, delay of the section
driven by motor 1: adjustable from 0 to 30 seconds.
Note: If the opening/closing time is less than the set delay time, the delayed section closes at the end of the closing time. If the
sections must be opened or closed at the same time, set the trimmer to minimum. In this case, the impact is always excluded.

OPERATING LOGIC

Step by step step
Automatic
PARK FUNCTION (Only in automatic)
No pulses are detected during opening and pause
Excluded
IMPACT
Excluded
Included
CLOSING PHOTOCELL OPERATION
Stops and reverses the motion
Stops and starts again after receiving the release
Note: all adjustments are performed with the control unit switched off and the gate closed.
GATE
STATUS
(total opening)
CLOSE
OPEN
CLOSING
OPENING
Restarts the motion in the opposite
STOPPING
Opens/completes the pause and stops.
CLOSE
If the pulse continues, the pause is
suspended until the release occurs
Closes immediately. If the problem persists,
OPEN IN
additional pulses are stopped and the pau-
PAUSE
se is suspended until the release occurs
CLOSING
OPENING
Restarts the motion in the opposite
STOPPING
11. ADJUSTMENTS WITH TRIMMER
12. DIP-SWITCH SETTINGS (SW1)
13. OPERATING LOGIC
PULSE B
PULSE A
(single section
opening)
Opens
Closes immediately
Stops operation and reopens
at the next step
Stops operation and closes
at the next step
direction
Stops and reopens
Stops and closes or no effect
as per dip-sw2
direction
PULSES
STOP
FTC CLOSES
Stops Pulse
Stops and reverses or blocks
Stops
and starts after reset as per
operation
and switches to
STOP mode
Stops pulse if for closing
Stops Pulse
Stops Pulse
Stops pulse and suspends the pause until the
Stops
operation
Stops and reverses or blocks
and switches to
and starts after reset as per
STOP mode
Stops Pulse
Stops pulse if for closing
Stops Pulse
7
1
2
3
OFF
ON
OFF
ON
OFF
ON
FTC OPENS
No effect
Stops Pulse
Stops Pulse
Stops Pulse and
starts again after
dip-sw 4
Stops and starts
No effect
again after reset
Stops Pulse
motion
No effect
Stops Pulse
release occurs
Stops Pulse and
starts again after
dip-sw 4
Stops and starts
again after reset
Stops Pulse
motion
ENGLISH
4
OFF
ON
reset
reset