2.2 HOLD-UP TIME
10msec (minimum) at 80% of full load at 230Vac input.
2.3 POWER GOOD DELAY
100-500 msec.
2.4 POWER FAIL DELAY
>1 msec.
2.5 TURN-ON DELAY TIME
2000 msec max.At nominal line full load.
2.6 TRANSIENT OVERSHOOT
DC output transient step sizes as below table:
Output voltage
Max. step size
Load-changing repetition rate of 10m seconds.
Load slew rated 1.0A/uS and capacitive load as below :
+5V
10000uF
2.7 RISE TIME
20ms max at full load.
3.0 PROTECTION:
ET550-HG/ET650-HG/ET750-HG(V1.0)
When OVP ,OPP ,OCP or short protection is triggered, the main outputs will be latched off.
The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto
recovery when fault condition removed.
ET550-HG/ET650-HG/ET750-HG (V1.1)
When OVP ,OPP ,OCP,OTP or short protection is triggered, the main outputs will be latched off.
The main outputs can be reset by cycling the DC remote on/off or AC power. +5Vsb output is auto
recovery when fault condition removed.
3.1 OVER VOLTAGE PROTECTION
+3.3V output
+5.0V output
+12.0V output 15.6 Vmax.
3.2 SHORT PROTECTION
All output to GND.
05
+5V
30%
+3.3V
10000uF
10000uF
4.5 Vmax.
7.0 Vmax.
+3.3V
30%
+12V
-12V
470uF
+12V
60%
+5Vsb
3300uF