When removing the drain hose, some water
may remain in the hose or the drain outlet.
Be sure this water will not spill by drying
the wet area before moving the unit.
NOTICE
When using the continuous draining feature,
ensure the unit is placed above the sink or drain
being used. This will ensure proper draining.
3. Pump draining (some models)
•
Water can be pumped from the unit
into a sink or other type of drain by
putting the unit in pump mode and
attaching the included pump hose.
Be sure to install both the inlet and
outlet pump hoses as shown in the
figures on the right.
•
To install the pump hose, remove the
plug from the pump drain hole and
firmly attach the the included pump
hose as shown in Fig. 12.
•
Initiate pump mode by holding both
the up and down arrows for three
seconds.
•
The pump inlet hose must be
placed in the bucket in order to
pump the water out of the bucket.
NOTICE
The pump may generate a loud noise
for the first 3~5 minutes of operation.
Drain hose
Reinstall the plastic cover
Max pump height: 14 ft.
Make sure the hose is
properly seated.
To remove the pump
hose, push in on the
collar around the hose
and pull the hose out.
Pump drain hose outlet
connection
Pump drain hose
inlet connection
Fig. 11
Pump drain
Pump drain
hose outlet
hose
Fig. 12
Fig. 13
Page 13