LD11 DIN Rail Dimmer
1) Mount the LD11 by snapping it into the DIN rail
and
connect
schematics.
2) Set the rotary code switches on the front side
to the desired address.
-When mounting more LD11 dimmers next to
each other, depending on the load per LD11,
keep an extra distance of 2 cm between each
LD11 to ensure the heat capacity.
-When using the LD11 with low voltage lights,
install the transformer as if it was the lamp
indicated in the wiring diagram.
With the help of additional momentary switches
on input 2, the module can be switched on or off
by a short key press and can be dimmed by a
long key press.
LD11: 230V / 50Hz – 60W minx. – 700W max. – low
voltage halogen compatible for most halogen
transformers.
FD10 Phase Coupler/Filter
Mount the FD10 by snapping it into the DIN rail
and
connect
schematics.
1) Coupling and Filtering
2) Coupling without Filtering
FD10: 230V/50Hx – 63A
AD10, FD10, LD11,
the
wiring
the
wiring
according
according
033000=13684C
the
the
5