Congratulations on your purchase of a Brink's™ outdoor Metal Halide area security lighting xture. You have purchased a safe, dependable, easy-to-install security lighting system. You can use this xture at home
for outdoor lighting applications.
WHAT IS INCLUDED:
A – Main Fixture Housing
B – Wiring Cover plate
C – Re ector/Lens Assembly
A
D – Metal Halide Lamp Bulb
E – Fixture Mounting Lag Screws (3)
F – Wiring Cover plate Screws (with washers and nuts) (2)
G – Lens Assembly Screws (Pre-installed) (3)
H – Green Ground Screw (1)
I – Wire Connectors (3)
J – Photocell (Model No. 7265)
K – Protective Lens Cover
TOOLS YOU WILL NEED:
C
Screwdriver, power drill with a 3/16" drill bit, and
adjustable wrench.
IMPORTANT SAFETY INFORMATION
IF YOU ARE NOT FAMILIAR WITH ELECTRICAL WIRING, IT IS RECOMMENDED THAT YOU SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN WHO CAN ASSURE THAT
THIS INSTALLATION MEETS LOCAL, STATE, AND NATIONAL CODES. BE SURE POWER IS TURNED OFF AT THE MAIN POWER PANEL OR FUSE BOX BEFORE INSTALLING
OR REPLACING THE FIXTURE. DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT.
• Before installing this xture, be sure to check with local ordinances regarding approved outdoor
lighting. This xture style may not be allowed in some areas.
• This xture is for outdoor use only.
• This xture is for WALL MOUNTING only.
• This xture is to be connected to a 120 volt, 60 Hz power source. Connecting to a different power
source may create a hazard and will void the warranty.
• This xture is suitable for wet locations.
• Do not touch hot lens, guard, or enclosure.
PRIOR TO INSTALLATION
Carefully read through the entire installation instructions before installing this security light xture.
Make sure all installation parts are included. Compare parts with package contents list above. If any part is missing or damaged, do not attempt to install product. Please contact customer service for replacement parts.
LOCATION
Select a location on a structurally sound, at wall 10-25 feet above the ground.
Fixture should be located on wall at least 18" below any overhang or other structural detail.
Fixture should not be recessed and must be positioned with bulb in vertical position with bulb
socket base up.
120 Volts, 60 Hz power must be available at the desired location. If not, have a quali ed
electrician route power to that location.
MOUNTING (For New Installations)
1. Using mounting template as a guide, mark the 3 mounting holes locations (Figure 1). Drill
3/16" pilot holes for lag screws (E).
2. Install 2 bottom lag screws rst (Figure 2). Screw in the lag screws (E) so that there is about
3/8" of space under the head.
3. Place the end of the housing arm on the 2 bottom lag screws (E) (Figure 3). Install the top lag
screw then tighten the other 2 screws.
D
G
F
H
E
I
• Ground Fault Circuit Interrupter (GFCI) is to be provided on the circuit(s) and checked for proper function
and operation.
• When replacing the lamp (bulb), use only a 100 watt metal halide lamp (bulb) of the same size.
• Lamp (bulb) gets HOT quickly.
• Do not look directly at lighted lamp (bulb).
• Do not attempt to open the xture housing. There are no serviceable parts inside.
• Always use safety precautions. Safety glasses and gloves should be worn during installation.
SAVE THESE INSTRUCTIONS
1
2
ACTUAL SIZE
MOUNTING TEMPLATE
2.75" (7 cm)
WIRING
1. Thread wires from the conduit or junction box through one of the "knock out" holes in the wiring cover plate
(Figure 4).
2. Secure the outdoor cable or exible conduit to cover plate (B) with a tting in accordance with local, state,
and/or national electrical codes.
3. Thread wires from xture through pre-existing hole in the wiring cover plate (B) (Figure 5).
4. Wire xture by connecting wires from the conduit or junction box with same colored wire from the xture
using supplied wire connectors (I).
a.
Connect black xture wire to black supply wire.
b.
Connect white xture wire to white supply wire.
c.
Connect green xture wire to green (or bare) supply grounding wire.
5. Install the wiring cover plate (B) onto housing arm and secure with 2 screws, washers, and nuts (F) provided.
Make sure that all connections are encapsulated and that no wires are pinched by the cover plate (B).
REFLECTOR/LENS INSTALLATION
J
1. Align large holes in the base of re ector/lens (C) with screws heads.
2. Push re ector/lens (C) until seated into the main xture housing (A).
3. Rotate re ector/lens counterclockwise to engage keyed holes with the screws (G).
4. Tighten screws (G). Be careful not to over tighten.
B
PHOTOCELL INSTALLATION
1. Align photocell prongs with the photocell socket (Figure 8). It will only plug in one way. Plug in and twist
clockwise until it stops (Figure 9).
2. Photocell (J) should be rmly seated.
Note: The "North" directional arrow that may be printed on the top of the photocell is not applicable when being
installed onto this Brink's high pressure sodium light. This directional arrow is provided only as a reference for use
on certain other compatible light xture models.
K
When power is initially turned on, the light may come on even in daylight. If this occurs, the light will turn off after
two or three minutes and will automatically reactivate at dusk. If an arti cial light source (e.g. automobile
headlights) should accidentally activate the photocell and turn off the unit, the unit may take approximately 5
minutes to cool down before turning back on.
BULB INSTALLATION AND RE-LAMPING (Changing the lamp bulb)
Caution: Prior to installing check that the bulb (D) is of the proper type and wattage. Observe bulb manufacturer's
recommendations on lamp operation, ballast type, and burning positions.
1. Be sure power is OFF.
2. Remove protective lens cover (K) (Figure 10).
3. Remove old bulb by unscrewing counterclockwise.
4. Place bulb into bulb socket and screw bulb securely into bulb socket until it is rmly seated.
5. Replace protective lens cover (Figure 11).
6. Turn power ON.
CLEANING
3
Caution: Be sure xture temperature is cool enough to touch. Be sure power is OFF.
Clean re ector and front housing with mild soap or household type detergent. Do not use acid, ammonia, or
any other caustic solvent based cleaners.
TROUBLE SHOOTING CHECKLIST
If this xture fails to operate properly, check to make sure that...
1. The correct bulb is properly installed.
2. The bulb is not faulty.
3. The main power or wall switch is ON.
4. The photocell is seated properly.
5. The photocell is not damaged or faulty.
6. There is no light being re ected back into the photocell causing the xture to turn off.
7. The photocell is not blocked or covered.
8. The line voltage at the xture is correct.
9. The xture is wired correctly or that none of the wiring is loose.
10. The xture is grounded properly.
QUESTIONS: For further assistance or more information,please call 1-800-562-5625, 8 am – 5 pm (Paci c Time),Monday – Friday.
LIMITED LIFETIME WARRANTY – This product is warranted to be free from defects in material and workmanship for life of product. If a defect occurs, call 1-800-562-5625 for instructions on
how to have defective product repaired or replaced free of charge. LIMITATIONS - This warranty only covers Brink's assembled lighting products and accessories and is not extended to other
components, Lamp Bulb(s), or equipment used on the product. Warranty extends to original purchaser of product. Receipt or other approved proof of purchase required for warranty service.
NOT LIABLE FOR INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This warranty gives you speci c legal rights, and you may also have other rights which vary from state to state. NOT COVERED - Product failure not relating
to faulty material or workmanship, corrosion of brass components, reimbursement for installation or unauthorized service.
Hampton Products International Corp
50 Icon
Foothill Ranch, CA 92610-3000
1-800-562-5625
INSTALLATION INSTRUCTIONS
METAL HALIDE AREA SECURITY LIGHT
4
B
6
I
Conduit and Junction Box not shown
8
10
11
Brink's trademark & copyright work are used with permission.
SERIES 7252
5
7
F
9
J
Made in China
©2015 Hampton Products International Corp.
999-00108_7252_REVD 09/15

Publicidad

loading

Resumen de contenidos para BRINKS 7252 Serie

  • Página 1 INSTALLATION INSTRUCTIONS SERIES 7252 METAL HALIDE AREA SECURITY LIGHT WIRING NOTE: IF FOR ANY REASON YOUR PURCHASE OF THIS PRODUCT HAS NOT BEEN A POSITIVE EXPERIENCE, PLEASE CALL OUR CUSTOMER CARE HOTLINE AT 1-800-562-5625 1. Thread wires from the conduit or junction box through one of the “knock out” holes in the wiring cover plate BEFORE RETURNING YOUR PRODUCT.
  • Página 2 INSTRUCCIONES DE INSTALACIÓN SERIES 7252 LÁMPARA DE SEGURIDAD DE ÁREA DE HALURO DE METAL CABLEADO NOTA: SI POR CUALQUIER RAZÓN SU COMPRA DE ESTE PRODUCTO NO HA SIDO UNA EXPERIENCIA POSITIVA, SÍRVASE LLAMAR A NUESTRA LÍNEA DIRECTA DE ATENCIÓN AL 1.