Disposal; Troubleshooting; Spare Parts; Accessories - Honeywell MiniPlus FF06 Instrucciones De Montaje

Ocultar thumbs Ver también para MiniPlus FF06:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
If rinsing is into a container, then a suitable container
must first be put underneath.
1. Open the ball valve by turning the rinse knob
o Rinse knob must be vertical
2. Close the ball valve after approximately 15 seconds
A longer reverse rinse period may be necessary if the
filter is very dirty (Replace filter mesh see Servicing)
8.2 Servicing
8.2.1 Replace filter mesh
1. Close shutoff valve on inlet
2. Release pressure on outlet side (e.g. through water tap)
3. Close shutoff valve on outlet
4. Unscrew filter bowl
o Use double ring wrench ZR06F
5. Replace filter mesh
6. Place O-ring onto filter bowl
7. Screw in filter bowl hand-tight (without tools)
8. Slowly open shutoff valve on inlet
9. Slowly open shutoff valve on outlet

10. Troubleshooting

Problem
Too little or no water pressure

11. Spare Parts

No. Description
1 Clear filter bowl
complete with sieve
and mesh carrier
2 O-ring set for
mesh carrier
(pack of 10)
3 Replacement
sieve
4 O-ring set
for filter bowl
(pack of 10)
5 Doppelringschlüssel
zum Lösen der
Filtertasse (o. Abb.)
Spare parts can be purchased separately only in addi-
tion.
Honeywell GmbH
Cause
Shutoff valves upstream or downstream
from filter not fully open
Filter mesh dirty
Not fitted in flow direction
Part No.
/
"
KF06-1/2A
1
2
/
" - 1
/
"
KF06-1A
3
1
4
4
/
"
0903127
1
2
/
" - 1
/
"
0903128
3
1
4
4
/
"
AS06-1/2A
1
2
/
" - 1
/
"
AS06-1A
3
1
4
4
/
"
0901246
1
2
/
" - 1
/
"
0901499
3
1
4
4
/
" - 1
/
"
ZR06F
1
1
2
4
GB
8.3 Cleaning
Caution !
Do not use any cleaning agents containing solvents
and/or alcohol to clean the plastic parts!
If necessary, the filter bowl and the filter can be cleaned.
Frequency: every 6 month (depending on local opera-
ting conditions)
To be carried out by an installation company
Detergents must not be allowed to enter the environ-
ment or the sewerage system!
1. Close shutoff valve on inlet
2. Release pressure on outlet side (e.g. through water tap)
3. Close shutoff valve on outlet
4. Unscrew filter bowl
o Use double ring wrench ZR06F
5. Remove filter, clean and reinsert
6. Place O-ring onto filter bowl
7. Screw in filter bowl hand-tight (without tools)
8. Slowly open shutoff valve on inlet
9. Slowly open shutoff valve on outlet

9. Disposal

• Body of dezincification resistant pressed brass
• Brass threaded connections
• Stainless steel fine filter
• Red-bronze or shock-resistant, clear transparent synthetic
material filter bowl
Observe the local requirements regarding correct waste
recycling/disposal!
Remedy
Open the shutoff valves fully
Clean or replace filter
Fit filter in flow direction

12. Accessories

RV277 Inlet check valve
Available in sizes R
VST06 Connection set
Connection set
A = Threaded male connection;
B = Solder union connection
5
/
" - 2"
1
2
MU1H-1115GE23 R0609

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Miniplus ff06-aam

Tabla de contenido