Tabla de contenido

Publicidad

DEFAULT VALUES

RS232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay
disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled,
serial trigger lock disabled.
DATA FORMAT
length not transmitted, no header, terminator = CR-LF, character
replacement disabled.
RS232 Nixdorf DEFAULT SETTINGS
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking
hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec.,
ack/nack disabled, FIFO disabled, serial trigger lock disabled.
DATA FORMAT
length not transmitted, no header, terminator = CR, character
replacement disabled.
RS232 Fujitsu DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay
disabled, rx timeout 2 sec., ack/nack disabled, FIFO enabled,
serial trigger lock disabled.
DATA FORMAT
length not transmitted, no header, terminator = CR, character
replacement disabled.
RS232 ICL DEFAULT SETTINGS
9600 baud, parity even, 8 data bits, 1 stop bit, handshaking RTS
always on, delay disabled, rx timeout 9.9 sec., ack/nack disabled,
FIFO enabled, serial trigger lock disabled.
DATA FORMAT
length not transmitted, no header, terminator = CR, character
replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition
enabled, num lock unchanged, inter-character and inter-code
delays disabled, control character emulation = ctrl+shift+key.
DATA FORMAT
length not transmitted, no header, terminator = ENTER,
character replacement disable.
PEN EMULATION DEFAULT SETTINGS
interpret mode, conversion to code 39 disabled, output level
normal, idle level normal, minimum output pulse 600 µs,
overflow medium, inter-block delay disabled.
POWER SAVE
scan rate 270scans/s, standby disabled, sleep state disabled,
enter sleep timeout 0.6 sec.
READING PARAMETERS
operating mode hand-held, hardware trigger, trigger signal =
level, no trigger timeout, Flash On = 1 sec, Flash Off = .6 sec,
one read per cycle, safety time .5 sec, beeper intensity high,
tone 2, beeper type monotone, beeper length short, good read
spot duration medium.
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control
enabled, Puzzle Solver™ disabled, decoding safety = one read.
: code identifier disabled, no field adjustment, code
: code identifier enabled, no field adjustment, code
: code identifier enabled, no field adjustment, code
: code identifier enabled, no field adjustment, code
: code identifier disabled, no field adjustment, code

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gryphon d200

Tabla de contenido