Assembly Instructions

Important!
• System lines must be laid out in a conduit.
• The components of the electric T-junction must be installed only when they are in
a dead condition.
When using other cables for the system line, note the different colour coding. The
outer diameter must not exceed 7.5 mm.
6.1
Remove the shielding (a) of the system line (approx. 40 mm).
6.2
Place the union nut (c) on the system line (b) up to the stop.
The cable cores are marked with numbers 1 through 4
A: Union nut
B: FAR-Order-No. 2000104272
FAR-Order-No. 2000104274
FAR-Order-No. 2000100801
FAR-Order-No. 2000100852
6.3
Latch the cable cores (d) into the cable core guides (e) according to their colours.
6.4
Cut off the protruding ends of the cable core so that they are flush, i. e. so that they
do not protrude.
6.5
Place the union nut (c) on the electric T-junction (f) and tighten with the required
torque (1.2 Nm).
Important!
Ensure correct polarity.
Each cable core colour must be in the same cable core guide on both union nuts.
When the union nut is being tightened, the electric contact and the pull-relief are
automatically established.
Special seals provide protection against dust and water.
A
1
brown
2
white
3
blue
4
black
B
red
white
blue
black
5