5.
Application
Complete installation kit AQUALINE - Urinal flush valve DN 15 according to DIN 3265
Part 3, with fitting group II for in-wall installation with pushbutton operation. Flow rate
and flush water volume adjustable.
6. Technical Specifications
Flow pressure:
Calculation flow rate:
Flushing flow:
Flush water volume:
7.
Scope of Delivery
Item
Description
1
Cover plate with pushbutton activation
2
Plastic hose (2x)
3
Self-closing cartridge element
4
Mounting material
5
Mounting frame (fastened in cover plate)
Installation and Operating Instructions
8. Dimensions
9. Installation Example
10. Assembly Instructions
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
10.1 Remove the screws (b).
10.2 Cut shell protection (a) so it is flush with the front edge of the tiles.
☞
Important!
Do not remove the circlip.
10.3 Use a screwdriver with a blade width of 8 mm to close the water volume regulator.
1.0 - 4.0 bar
0.30 l/s
0.30 - 0.70 l/s
2-4 l adjustable