EMPTYING SOLUTION TANK
1. Connect black recovery hose at front of machine
and remove solution tank lid.
2. Press vacuum/blower switch towards vacuum
symbol.
3. Extract remaining rinse solution from solution tank
and flush tank with clean water (Figure 31).
4. Turn off machine, unplug power cord and drain
recovery tank.
OTHER CLEANING USES WITH MACHINE
BLOWER HOSE CLEANING
Use gray blower hose to blow out debris from hard to
reach areas and to remove dust and cobwebs from
overhead fixtures and vents (Figure 32).
ATTENTION: Do not use machine for dry pick–up.
Quick Cleant 1500 (07–00)
FIG. 31
FIG. 32
Home
Find... Go To..
CARPET CLEANING (OPTION)
Machine can be used to clean carpet with the use of
an optional carpet cleaning floor tool (See OPTIONS).
1. Connect fill–hose (supplied with machine) to water
faucet and fill tank with 15 gallons (57L) of hot
water, 140 F (60 C) maximum temperature.
DO NOT ADD CLEANING AGENTS TO
SOLUTION TANK, certain cleaning agents may
damage pump. Use a pump–up sprayer to apply the
cleaning agent mix to the carpet.
WARNING: Flammable materials can cause
an explosion or fire. Do not use flammable
materials in tank(s).
2. Use the equipped vacuum and solution hoses and
connect them to floor tool and then to front of
machine (Figure 33).
FIG. 33
3. Turn the FORMULA ON/OFF lever to the OFF
position, located at front of machine (Figure 34).
FIG. 34
OPERATION