SAFETY WARNINGS FOR THE APPLIANCES USING
R290 COOLING FLUID (PROPANE)
Propane is a natural gas that doesn't affect the environment but is inflammable.
It is therefore indispensable to check that the cooling circuit tubing is not damaged before connecting
the equipment to the mains.
For every 8gr. of cooling fluid, the installation location must have a minimum volume of 1 cubic metre.
The amount of cooling fluid in the appliance is indicated on the technical data plate in the tank.
Leakage of cooling fluid: avoid naked flames or over sources of ignition at the seat of the leakage.
Be careful not to damage the cooling fluid circuit during positioning , installation or cleaning. Avoid
flames or sparks inside the equipment.
Warning! Do not damage the cooling fluid circuit
Warning! Do not damage internal or external walls of the machine: the cooling fluid circuit may
damage. In case of damaged walls do not start the machine and refer to a service centre.
Warning! In case of damaged cooling fluid circuit, do not start the machine and refer to a service centre.
Warning! Keep clear of obstruction all ventilation openings in the appliance enclosure or in the
structure for building-in.
Warning! Do not use electrical appliances inside the food storage compartments of the appliance,
unless they are of the type recommended by the manufacturer.
Warning! Do not store explosive substences such as aerosol cans with flammable propellant in this aplliance.
INSTALLATION
Take out packaging and clean all the cabinet using
warm water together with 5% of neutral soap then dry
it with a soft cloth; for the glass parts only use specific
products, avoiding the use of water which can leave
on the glasses limestone residues.
Keep a distance from the wall of 10 cm. at least.
Cabinet must be installed on a perfectly even surface
(please settle the adjustable feet), far away from any
heat source (radiators, stoves, etc) including sun rays.
Good running of the cabinet can be compromised in
cases where the airflow is disturbed (wind, ventilators,
air conditioning outlets, etc).
Smooth running of the cabinet is assisted when suf-
ficient air is permitted to flow through the bottom of
the unit; it is very important that the grills at the base
are kept uncovered.
Do not expose the cabinet to rain.
Install and position the unit in such a way so as to allow
easy access to the power socket.
Never use electrical equipment in the refrigerated
compartment
Never place containers of liquid on or immediately
above the ticket counter; should the content spill out,
it would damage the counter.
INFORMATIONS ABOUT USE
-6-
10 cm