Features
This product is the clear type dome cover.
WV-CW7CN is applied with ClearSight coating (rain wash coating).
Precautions
Refer installation work to the dealer.
Installation work requires technique and experiences. Failure to observe this may cause fi re, electric
shock, injury, or damage to the product.
Be sure to consult the dealer.
The screws and bolts must be tightened to the specified torque.
Failure to observe this may cause a drop resulting in injury or accidents.
Installations
Refer to the operating instructions of the camera in use.
Step 1
Remove the enclosure from the camera
body
Loosen the 4 enclosure fixing screws using the
bit provided with the camera, and then remove
the enclosure from the camera body.
Enclosure
Camera body
2
Enclosure fixing
screws (4 pcs.)
Step 2
Remove the dome cover
Remove the 3 dome cover fixing screws (2
without washers, 1 with washer), and then
remove the dome cover holding plate, the
dome cover and the waterproof rubber from
the enclosure.
(The Dome cover holding plate and the camera
body are connected with the installation auxil-
iary wire. Please pay attention that the installa-
tion auxiliary wire will be removed at the
moment when the dome cover fixing screws
are removed.)
Keep the removed dome cover holding plate, 3
dome cover fixing screws until using them in
step 3.