Storing the Appliance
Illustration
 Store the suction hose and the mains
cable as shown in the illustration.
 Place the appliance in a dry room and
secure it from unauthorized use.

Transport

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
 Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance at the handle and at the suction
pipe to transport it.
 Grab the appliance by the chassis and
by the sliding bow to load it.
 Pull the device behind you at the carry-
ing handle for transporting it over longer
distances
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Storage

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Maintenance and care

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
 Open filter door.
 Replace the flat pleated filter.
 Close the filter door, it must lock into
place.
Replace the disposal bag
Illustration
 Release and remove the suction head.
 Put the disposal bag over.
 Pull the opening of the disposal bag out
toward the back over the suction sup-
port.
 Tightly seal the disposal bag with clo-
sure strips underneath the opening.
 Remove disposal bag.
 Attach the new disposal bag.
 Pull disposal bag over the container.
 Insert and lock the suction head.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug
and electrodes of the device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace the filled disposal bag
 Ensure the filter cover properly locks
into place.
 Replace the flat pleated filter.
 Check drain pipe for leaks.
Dust comes out while vacuuming
 Check for proper installation of the flat
pleated filter.
 Replace the flat pleated filter.
– 4