ALGOTECK CHARGING CURVE
BATTERY CHARGING STEPS
The ALGOTECH charging algorithm, unique on the market, is composed of 6 steps.
1
2
3
4
5
6
Voltage threshold
Boost
Absorption
Equalization
Floating
Nb: the voltage levels above are ajusted to ALGOTECK conditions
TEST
BOOST CHARGE
(I)
EQUALISATION
(max. 4 hours)
RECOND.
100%
LIFE+/STORAGE
UNIMPPT determines on a daily basis the health status and
charging status of your battery and determines the steps and
charging levels required for the maintenance of your battery.
UNIMPPT uses 100% of the energy from the solar panel, until
the voltage reaches the equalization level. The battery is
charged at 80%.
UNIMPPT equalises the charge on all battery elements
(battery charged at 100%)
Only in liquid mode, this step stirs, thanks a pulsed current,
the electrolyte of your battery to avoid all stratification or
sulfation phenomena.
The battery charge is done. The green "load" light starts
blinking. UNIMPPT continues to deliver a low current to
compensate the battery's self-discharge.
UNIMPPT compensates the battery's natural self discharge,
with a pulse charge for a longer battery lifespan.
Gel
14,2 V
-
-
13,9V
www.uniteck.fr
AGM
Liquid
14,4 V
14,5 V
14,4V
14,5V
-
14,8V
13,9V
13,9V
EN
33/59