Value range:
4 mA corresponds to
20 mA corresponds to 1023 °C / 1874 °F
Measures to be taken if the heating element or tool protection trips
• Remove tool from mains (LINE/MAINS). The electronics are automatically reset after 5 seconds
• Check air supply
• Check air volume
Operation LE MINI SENSOR KIT
• The tool must be connected by a qualified electrician in accordance with the circuit diagram on page 3.
• Fit the nozzle appropriate to the use.
Danger – can cause burns! Do not touch the heating element tube and nozzle while they are hot.
Allow the device to cool down before replacing the nozzle / reflector.
• Connect the air supply at the compressed air connection (8).
• Set the air flow at the pressure reduction valve (3) (min. air flow, max. pressure - see technical data page 2)
• Switch on at main switch (2)
• Set the required hot air temperature at the temperature regulator CSS (5).
• After use let the tool cool down by allowing cold air to flow through (avoiding a build up of heat).
Attention: always operate device with air supply !
Function heat element protection
• If the heating element overheats, the heater is switched off through the converter integrated in the connection
box (4). The shutdown is indicated on the fault indicator (6).
Function tool protection
• If the tool overheats, the heater is switched off through the converter integrated in the connection box (4). The
shutdown is indicated on the fault indicator (6).
Measures to take in the case of switching off through the heating element protection and tool protection
• Switch off the tool at the main switch (2)
• Check the compressed air
• Check the air flow rate
Training
• Leister Technologies AG and its authorised service points provide free courses in the area of applications.
3D drawings
• 3D drawings of available from your Service Centres or at www.leister.com
Accessories
• Only Leister accessories may be used.
• Accessories at www.leister.com
Service and repairs
• Repairs should only be carried out by authorised Leister Service Centres. They guarantee a correct and reliable
repair service within reasonable period, using original spare parts in accordance with the circuit diagrams
and spare parts lists
Warranty
• For this tool, the guarantee or warranty rights granted by the relevant distributor/seller shall apply. In case of
guarantee or warranty claims any manufacturing or workmanship defects will either be repaired or replaced by the
distributor at its discretion. Warranty or guarantee rights have to be verified by an invoice or a delivery document.
Heating elements shall be excluded from warranty or guarantee.
• Additional guarantee or warranty claims shall be excluded, subject to mandatory provisions of law.
• Warranty or guarantee shall not apply to defects caused by normal wear and tear, overload or improper handling.
• Warranty or guarantee claims will be rejected for tools that have been altered or changed by the purchaser.
0 °C /
32 °F
• Check air flow
• Re-connect tool to the mains
• Check the through flow of air
• Switch on the tool at the main switch (2)
17