Installation Procedure - Panasonic TY-WK103PV9 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28

Installation procedure

1. Confirm the strength of the installation location.
 The weight of the wall-hanging bracket is approximately 25 kg (55.1 lbs.). For the weight of the plasma
display attached to the wall-hanging bracket, please see manual for the plasma display.
 Check the wall strength at the 16 attachment locations by referring to the dimension drawing of the wall-
hanging bracket, and provide adequate reinforcement if strength is not sufficient.
451.1
L
60
120
Wall attachment holes (16 locations)
2. Install the wall-hanging bracket to the wall.
 Based on the dimension drawing, find the positions of the holes which will be used to mount the brackets on
the wall, and mount the brackets on the wall.
 (When installing the brackets horizontally) Mount the wall-hanging brackets with the arrows marked on
them pointing up. Mount the end of the bracket marked "L" on the left and the end marked "R" on the right.
(When installing the brackets vertically) Mount the end of the bracket marked "L" at the top and the end
marked "R" at the bottom.
 Use commercially available bolts or nuts with a nominal diameter of 12 mm (0.5 inches) to secure the
brackets at all 16 mounting holes.
Horizontal installation
Safety catch
Safety catch
anchoring screw
L
Marks (H)
(For horizontal
installation)
Caution
● Use commercially available bolts with a nominal diameter of 12 mm (0.5 inches) that are suited to the wall material.
● Check the strength of the mounting bolts, and use bolts which are strong enough.
Note
● The marks indicate the center line of the Plasma Display.
● It is recommended that you leave a maintenance space of at least 70 cm (27.6 inches) behind the plasma display.
12
1706
1512
451.1
R
60
120
Unit: mm
Vertical installation
Safety catch
anchoring screw
R
Caution
● The wall-hanging bracket has attachment holes
provided in 16 locations.
Be absolutely sure to attach each bracket in all
16 locations.
* Refer to page 70 and 71 for the detailed
dimensions that apply when installing the plasma
display.
Plasma display external dimensions
Marks (V)
(For vertical
installation)
Safety catch
anchoring screw
Safety catch