Setting The Temperature - Pahlen Aqua HL Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Electric heater Aqua HL line
Starting
1. Start the pool water circulation pump.
Check that the water is circulating normally in the installation before switching on the heater. The heater must be completely
full of water before the power is switched on.
2. Switch on the power to the heater.
3. Set the desired pool temperature.
4. Check the flow switch by turning off the flow of water through the heater with a shut-off valve. The contactor should trip.
5. Turn on the water. The contactor should now close (after 15 sec.).
6. The heater will now heat the pool water to the desired temperature.

Setting the temperature

Press once (on the blue or red arrow key) - the display starts to flash and the set temperature is displayed.
Change the temperature up and down with the arrow keys until the required temperature is set.
Red = warmer, blue = colder in steps of 0,5°C.
After the setting is completed, the display will return to showing the actual pool temperature with
a fixed light.
Operation
For the heater to work, the pool water must be circulating.
The yellow LED marked "Heating" is lit when the heater is working and goes out when the correct temperature has been reached.
The display constantly shows the current temperature of the water. The set temperature can be changed at any time (see Setting
the temperature). To see the set temperature, press once
(the display flashes). NOTE: The set temperature is retained in the
memory after a power failure.
NOTE: Always switch off the power to the heater before
backwashing and before cleaning the filter.
Trouble shooting
If the heater does not start:
1. Check the fuses
2. The overheating protection may have tripped:
-Losen the protective cap, see fig beside.
-Press the reset button on the connection box.
-Put the cap back.
3. Check the flow rate. The flow switch in the heater is designed
for a minimum flow of 90 litres/min.
4. Set the thermostat to a higher temperature.
Error codes
E1 = flow switch, circulation pump
E2 = pool sensor
E7 = control circuit contactor, overheating limit control
Hi = pool temperature above +45ºC +45ºC
A ( 1 : 1 )
Protective cap
Cap
A
Surface treatment
E
The tolerance class in accordance with this
part of ISO 2768-1
Demontering lock
överhettningsskydd
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
10
ENGLISH
29.5
A ( 1 : 1 )
Protective
Cap
cap
Reset button
Reset button
A
Designed by:
Drawn by: Date
Approved by:
TS
2012-06-21
Assembly drawing no.
Art.no.
Surface treatment
Designed by:
E
Scale
Revised by: Date
The tolerance class in accordance with this
Assembly drawing no.
part of ISO 2768-1
Drawing number
Rev.no.
M11668 0
Demontering lock
överhettningsskydd
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
Drawn by: Date
Approved by:
TS
2012-06-21
Art.no.
Scale
Revised by: Date
Drawing number
Rev.no.
M11668 0

Publicidad

Tabla de contenido
loading

Tabla de contenido