General
Caution
The flat pleated filter must must always
be in place while vacuuming.
If wet dirt is vacuumed with the upholstery or
–
crevice nozzle, or if water is sucked up from a
container, it is recommended to deactivate the
"automatic filter cleaning" function.
If the maximum liquid level is reached the ap-
–
pliance will turn off automatically.
In case of non-conductive liquids
–
(such as emulsion drilling fluids, oils,
and greases) the appliance is not
turned off when the container is full.
The filling level must be continuously
monitored and the container must be
emptied in time.
After the wet vacuuming: Clean the flat folded
–
filter with the filter cleaning. Clean the elec-
trodes with a brush. Clean the container with a
damp rag and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip system. All
accessories with a nominal width of 35 mm can be
connected.
Operation
Turning on the Appliance
Plug in the main plug.
Switch on the appliance at the main switch.
Adjust the suction output
ISS 35-S automatic, ISS 55-S automatic
only:
Set the suction output (min - max) at the rotary
switch.
Working with electrical power tools
ISS 35-S automatic, ISS 55 automatic, ISS
55-S automatic only:
Danger
Risk of injury and damage! The socket
outlet is only for the connection of power
tools to the vacuum cleaner. Any other
use of the socket outlet is not permitted.
Connect the mains plug of the electric power
tool to the vacuum cleaner.
Switch on the appliance at the main switch.
Switch on the automatic remote control:
–
Press the bottom switch. The vacuum cleaner is
turned on and off automatically with the elec-
tric power tool.
Switch off the automatic remote control:
–
Press the top switch.
Note: The vacuum cleaner starts automatically
within 0.5 seconds and continues to run for 15 sec-
onds after the power tool has being switched off.
Note: Please refer to "Technical specifications"
for the power connection specifications of the pow-
er tools.
Illustration
Adjust the stepped power tool adaptor to fit
the connection of the electric power tool.
Illustration
Remove the elbow from the suction hose.
Attach the stepped power tool adaptor to the
suction hose.
Illustration
Connect the adaptor to the electric power
tool.
3
15