EN
DE
FR
Tone
Tone Type
1.
970Hz (BS5839-1:2002)
2.
800Hz/970Hz @ 2Hz (BS5839-1:2002)
3.
800Hz – 970Hz @ 1Hz (BS5839-1:2002)
4.
970Hz 1s OFF/1s ON (Apollo Fire Systems Alert Tone, BS5839-1:2002)
5.
970Hz, 0.5s/ 630Hz, 0.5s (Apollo Fire Systems Evacuate Tone, BS5839-1:2002)
6.
554Hz, 0.1s/ 440Hz, 0.4s (France – AFNOR NF S 32 001 )
7.
500 – 1200Hz, 3.5s/ 0.5s OFF (Netherlands – NEN 2575:2000 Dutch Slow Whoop)
8.
420Hz 0.625s ON/0.625s OFF (Australia AS1670 Alert tone)
9.
500 – 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (Australia AS1670 Evacuation tone)
10.
550Hz/440Hz @ 0.5Hz
11.
970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 Low tone)
12.
2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201 High tone)
13.
1200Hz – 500Hz @ 1Hz (DIN 33 404)
14.
400Hz
15.
550Hz, 0.7s/1000Hz, 0.33s
16.
1500Hz – 2700Hz @ 3Hz (Vandal Alarm)
17.
Simulated Bell
18.
840Hz
19.
660Hz
20.
660Hz 1.8s ON/1.8s OFF
21.
660Hz 0.15s ON/0.15s OFF
22.
510Hz, 0.25s/ 610Hz, 0.25s
23.
800/1000Hz 0.5s each (1Hz)
24.
250Hz – 1200Hz @ 12Hz
25.
500Hz – 1200Hz @ 0.33Hz.
26.
2400Hz – 2900Hz @ 9Hz
27.
2400Hz – 2900Hz @ 3Hz
28.
800Hz – 970Hz @ 100Hz
29.
800Hz – 970Hz @ 9Hz
30.
800Hz – 970Hz @ 3Hz
31.
800Hz, 0.25s ON/1s OFF
32.
500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220)
33.
340Hz
34.
1000Hz
35.
1400Hz – 1600Hz, 1s/1600Hz – 1400Hz, 0.5s (NF 48-265)
36.
660Hz 6.5s ON/13s OFF
37.
1000Hz/2000Hz, 1s each
38.
720Hz, 0.7s ON/0.3s OFF
39.
970Hz, 0.25s ON/OFF
40.
2800Hz, 1s ON/OFF
41.
2800Hz 0.25s ON/OFF
42.
2400/2900 @ 2Hz
43.
Chime, 554Hz/440Hz Single shot 'ding dong'
44.
Chime, 554Hz/440Hz Repeating 'ding dong'
45.
Chime, 970Hz/800Hz Single shot 'ding dong'
46.
Chime, 970Hz/800Hz Repeating 'ding dong'
47.
Hooter, Repeating
48.
Gentle alarm - Tone 2, rises slowly to full volume over 30s
49.
Time-Out Alarm – As Tone 2, cuts off after 10 mins
50.
Time-Out Alarm – As Tone 2, cuts off after 2 mins
51.
750Hz 0.33s ON/0.51s OFF
52.
750Hz 0.51s ON/0.33s OFF
53.
550Hz, 0.33s/1000Hz, 0.7s
54.
600Hz – 900Hz/ 0.9s
55.
660Hz – 680Hz/ 0.9s
56.
670Hz – 725Hz/ 0.9s
57.
920Hz – 750Hz/ 0.9s
58.
700Hz - 900Hz, 0.3s/0.6s OFF
59.
900Hz - 760Hz, 0.6s/0.3s OFF
60.
750Hz
61.
Power Only – Use with Stage 3 control for manual/intermittent chime triggering
62.
Power Only – Use with Stage 3 control for manual/intermittent chime triggering
63.
Power Only – Use with Stage 3 control for manual/intermittent horn triggering
64.
Reserved for future use
EN54-3:2001+A1
Fire Alarm Device – Sounder
Type B: For indoor or outdoor use
PNS-0001/PNC-0001/02/20/41/43/24/28/45/46/47
Technical Data: Document 18-186528
Texecom Ltd (Incorporating Klaxon Signals)
St Crispin Way, Haslingden, BB4 4PW, UK
+44 1706 233879
NL
ES
PT
Tone Description / Application
+44 1706 223450
IT
SE
PL
Nexus 105 DC Sounder & Sounder-Beacon
Installation Instructions
Dip Switch
(S1/S2)
O-O-O-O-O-O
O-O-O-O-O-I
O-O-O-O-I-O
O- O-O -O-I- I
O-O-O-I-O-O
O-O-O - I-O -I
O-O- O - I-I- O
O - O - O - I - I - I
O-O-I-O-O-O
O- O-I- O-O-I
O-O- I- O-I- O
O - O - I - O - I - I
O- O-I- I-O- O
O - O - I - I - O - I
O - O - I - I - I - O
O - O - I - I - I - I
O-I-O-O-O-O
O-I- O -O- O-I
O- I-O -O- I-O
O - I - O - O - I - I
O-I- O -I- O-O
O - I - O - I - O - I
O - I - O - I - I - O
O - I - O - I - I - I
O- I- I- O-O-O
O - I - I - O - O - I
O - I - I - O - I - O
O - I - I - O - I - I
O - I - I - I - O - O
O - I - I - I - O - I
O - I - I - I - I - O
O - I - I - I - I - I
I-O-O-O-O-O
I- O-O- O-O-I
I- O-O-O- I-O
I - O - O - O - I - I
I-O- O-I- O-O
I - O - O - I - O - I
I - O - O - I - I - O
I - O - O - I - I - I
I- O- I-O- O-O
I - O - I - O - O - I
I - O - I - O - I - O
I - O - I - O - I - I
I- O - I - I - O - O
I - O - I - I - O - I
I - O - I - I - I - O
I - O - I - I - I - I
I- I-O- O-O- O
I - I - O - O - O - I
I - I - O - O - I - O
I - I - O - O - I - I
I - I - O - I - O - O
I - I - O - I - O - I
I - I - O - I - I - O
I - I - O - I - I - I
I - I - I - O - O - O
I - I - I - O - O - I
I - I - I - O - I - O
I - I - I - O - I - I
I - I - I - I - O - O
I - I - I - I - O - I
I - I - I - I - I - O
I - I - I - I - I - I
0832-CPD-0615 (Sounder-LED Beacon)
0832
0832-CPD-0616 (Sounder-Xenon Beacon)
07
0832-CPD-0617 (Sounder)
sales@klaxonsignals.com www.klaxonsignals.com
@
DK
3rd Stage
Peak Sound
Tone
Level
(dBA @1m, 24V DC) (mA Avg, 24V DC)
18
105
1
105
1
104
1
105
1
105
1
103
1
108
1
102
1
106
19
104
1
105
1
107
1
109
18
101
1
105
1
113
1
107
1
110
10
102
19
102
19
102
1
103
1
106
1
101
1
108
1
113
1
111
1
104
1
104
1
105
1
103
1
108
1
101
18
106
1
104
19
102
1
108
1
104
1
105
1
106
1
106
1
113
1
100
1
102
1
101
1
100
1
102
1
105
1
105
1
105
1
103
1
103
1
106
1
104
1
101
1
104
1
104
1
104
1
105
18
103
43
43
47
Issue 8.0 (June 2010) 18-186456-8
Copyright © Texecom Ltd
Sounder
Current
31
28
25
17
27
20
19
10
13
21
13
16
22
16
25
32
18
26
25
14
14
24
25
23
21
39
39
23
27
28
8
20
17
25
34
9
25
16
17
20
19
38
15
15
36
36
13
28
28
28
8
15
25
31
28
25
30
11
19
22