Klaxon Nexus 110 DC Instrucciones De Instalación

Publicidad

Enlaces rápidos

EN
DE
FR
Tone
Tone Type
1.
970Hz (BS5839-1:2002)
2.
800Hz/970Hz @ 2Hz (BS5839-1:2002)
3.
800Hz – 970Hz @ 1Hz (BS5839-1:2002)
4.
970Hz 1s OFF/1s ON (Apollo Fire Systems Alert Tone, BS5839-1:2002)
5.
970Hz, 0.5s/ 630Hz, 0.5s (Apollo Fire Systems Evacuate Tone, BS5839-1:2002)
6.
554Hz, 0.1s/ 440Hz, 0.4s (France – AFNOR NF S 32 001 )
7.
500 – 1200Hz, 3.5s/ 0.5s OFF (Netherlands – NEN 2575:2000 Dutch Slow Whoop
8.
420Hz 0.625s ON/0.625s OFF (Australia AS1670 Alert tone)
9.
500 – 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (Australia AS1670 Evacuation tone)
10.
550Hz/440Hz @ 0.5Hz
11.
970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 Low tone)
12.
2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201 High tone)
13.
1200Hz – 500Hz @ 1Hz (DIN 33 404)
14.
400Hz
15.
550Hz, 0.7s/1000Hz, 0.33s
16.
1500Hz – 2700Hz @ 3Hz (Vandal Alarm)
17.
Simulated Bell
18.
840Hz
19.
660Hz
20.
660Hz 1.8s ON/1.8s OFF
21.
660Hz 0.15s ON/0.15s OFF
22.
510Hz, 0.25s/ 610Hz, 0.25s
23.
800/1000Hz 0.5s each (1Hz)
24.
250Hz – 1200Hz @ 12Hz
25.
500Hz – 1200Hz @ 0.33Hz.
26.
2400Hz – 2900Hz @ 9Hz
27.
2400Hz – 2900Hz @ 3Hz
28.
800Hz – 970Hz @ 100Hz
29.
800Hz – 970Hz @ 9Hz
30.
800Hz – 970Hz @ 3Hz
31.
800Hz, 0.25s ON/1s OFF
32.
500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220)
33.
340Hz
34.
1000Hz
35.
1400Hz – 1600Hz, 1s/1600Hz – 1400Hz, 0.5s (NF 48-265)
36.
660Hz 6.5s ON/13s OFF
37.
1000Hz/2000Hz, 1s each
38.
720Hz, 0.7s ON/0.3s OFF
39.
970Hz, 0.25s ON/OFF
40.
2800Hz, 1s ON/OFF
41.
2800Hz 0.25s ON/OFF
42.
2400/2900 @ 2Hz
43.
Chime, 554Hz/440Hz Single shot 'ding dong'
44.
Chime, 554Hz/440Hz Repeating 'ding dong'
45.
Chime, 970Hz/800Hz Single shot 'ding dong'
46.
Chime, 970Hz/800Hz Repeating 'ding dong'
47.
Hooter, Repeating
48.
Gentle alarm - Tone 2, rises slowly to full volume over 30s
49.
Time-Out Alarm – As Tone 2, cuts off after 10 mins
50.
Time-Out Alarm – As Tone 2, cuts off after 2 mins
51.
750Hz 0.33s ON/0.51s OFF
52.
750Hz 0.51s ON/0.33s OFF
53.
550Hz, 0.33s/1000Hz, 0.7s
54.
600Hz – 900Hz/ 0.9s
55.
660Hz – 680Hz/ 0.9s
56.
670Hz – 725Hz/ 0.9s
57.
920Hz – 750Hz/ 0.9s
58.
700Hz - 900Hz, 0.3s/0.6s OFF
59.
900Hz - 760Hz, 0.6s/0.3s OFF
60.
750Hz
61.
Power Only – Use with Stage 3 control for manual/intermittent chime triggering
62.
Power Only – Use with Stage 3 control for manual/intermittent chime triggering
63.
Power Only – Use with Stage 3 control for manual/intermittent horn triggering
EN54-3:2001+A1
Fire Alarm Device – Sounder
Type B: For indoor or outdoor use
PNS-0013/PNC-0013/15/21/48/50/29/34/52/53/54
Technical Data: Document 18-186529
Texecom Ltd (Incorporating Klaxon Signals)
St Crispin Way, Haslingden, BB4 4PW, UK
+44 1706 233879
NL
ES
PT
Tone Description / Application
+44 1706 223450
IT
SE
PL
Nexus 110 DC Sounder & Sounder-Beacon
Installation Instructions
Dip Switch
(S1/S2)
O-O-O-O-O-O
O-O-O-O-O-I
O-O-O-O-I-O
O- O- O -O-I- I
O-O-O-I-O-O
O-O-O - I-O -I
O-O-O-I- I- O
O - O - O - I - I - I
O-O-I-O-O-O
O-O- I- O-O- I
O- O-I- O- I-O
O - O - I - O - I - I
O-O-I- I-O- O
O - O - I - I - O - I
O - O - I - I - I - O
O - O - I - I - I - I
O-I-O-O-O-O
O- I- O- O-O-I
O-I- O- O-I- O
O - I - O - O - I - I
O- I-O -I- O-O
O - I - O - I - O - I
O - I - O - I - I - O
O - I - O - I - I - I
O-I- I- O-O- O
O - I - I - O - O - I
O - I - I - O - I - O
O - I - I - O - I - I
O - I - I - I - O - O
O - I - I - I - O - I
O - I - I - I - I - O
O - I - I - I - I - I
I-O-O-O-O-O
I-O- O- O-O- I
I- O-O-O-I- O
I - O - O - O - I - I
I- O-O-I- O-O
I - O - O - I - O - I
I - O - O - I - I - O
I - O - O - I - I - I
I- O-I- O-O-O
I - O - I - O - O - I
I - O - I - O - I - O
I - O - I - O - I - I
I- O - I - I - O - O
I - O - I - I - O - I
I - O - I - I - I - O
I - O - I - I - I - I
I- I- O-O- O-O
I - I - O - O - O - I
I - I - O - O - I - O
I - I - O - O - I - I
I - I - O - I - O - O
I - I - O - I - O - I
I - I - O - I - I - O
I - I - O - I - I - I
I - I - I - O - O - O
I - I - I - O - O - I
I - I - I - O - I - O
I - I - I - O - I - I
I - I - I - I - O - O
I - I - I - I - O - I
I - I - I - I - I - O
0832-CPD-0618 (Sounder-LED Beacon)
0832
0832-CPD-0619 (Sounder-Xenon Beacon)
07
0832-CPD-0620 (Sounder)
sales@klaxonsignals.com www.klaxonsignals.com
DK
3rd Stage
Peak Sound
Tone
Level
(dBA @1m, 24V DC) (mA Avg, 24V DC)
18
110
1
110
1
110
1
110
1
110
1
107
1
110
1
105
1
110
19
107
1
110
1
112
1
110
18
105
1
111
1
116
1
112
1
113
10
109
19
108
19
107
1
107
1
111
1
105
1
110
1
116
1
116
1
110
1
110
1
110
1
108
1
110
1
106
18
111
1
110
19
108
1
113
1
106
1
110
1
113
1
113
1
115
1
104
1
107
1
106
1
106
1
107
1
109
1
109
1
109
1
106
1
107
1
111
1
109
1
105
1
107
1
110
1
109
1
110
18
107
43
43
47
Issue 9.0 (May 2012) 18-186458-9
Copyright © Texecom Ltd
Sounder
Current
45
44
43
25
39
24
28
9
13
26
19
16
34
21
33
46
26
34
31
16
17
28
44
24
31
45
45
42
43
43
10
29
18
47
44
31
41
26
25
22
21
43
15
15
36
36
13
44
44
44
12
25
41
37
33
33
41
15
28
39

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Klaxon Nexus 110 DC

  • Página 1 Nexus 110 DC Sounder & Sounder-Beacon Installation Instructions Tone Tone Type Tone Description / Application Dip Switch 3rd Stage Peak Sound Sounder (S1/S2) Tone Level Current (dBA @1m, 24V DC) (mA Avg, 24V DC) 970Hz (BS5839-1:2002) O-O-O-O-O-O 800Hz/970Hz @ 2Hz (BS5839-1:2002) O-O-O-O-O-I 800Hz –...
  • Página 2: Installation Instructions

    Nexus 110 DC Sounder & Sounder-Beacon Installation Instructions From Controller To Next Unit Beacon Sounder 1st Stage 2nd Stage 3rd Stage 1st Unit 2nd Unit Xenon Beacon LED Beacon Switch Installation Manual 60 flashes per min 30 flashes per min Single Flash Double Flash...
  • Página 3 Gehäuse ..........Stoßfestes Polykarbonat/ABS Température de fonctionnement ..... De -25°C à +70°C IP-Klasse ..........IP66 Matière ............ Polycarbonate résistant au choc Synchronisierung ........Automatisch mit Klaxon Nexus- Degré d'étanchéité ......... IP66 und Sonos-Alarmgebern Synchronisation ........Automatique avec d'autres sirènes Klaxon (SONOS & NEXUS) *je nach gewähltem Ton und Eingangsspannung.
  • Página 4: Montage Instructies

    Montage instructies Instrucciones de Instalación Installatie Instalación De signaalgever bovenzijde wordt van de basiseenheid gescheiden door de vier draaibevestigingen die zich in de hoeken van de signaalgever bevinden a. El receptor acústico se instala después de montar la unidad de base y (Aanbevolen schroevendraaier: Philips Nr.
  • Página 5: Manual De Instalação

    Manual de Instalação Istruzioni di installazione Instalação Installazione a. A instalação do besouro é feita montando primeiro a base e efectuando a. L'apparecchio acustico si installa in primo luogo montando l'unità di as ligações da cablagem exterior à base. A cabeça da unidade fica base e collegando quindi i cavi esterni alla base.
  • Página 6: Instrukcja Montażu

    Instrukcja montażu Installationsmanual Instalacja Installation a. Sirenen installeras genom att först montera basenheten och sedan göra den externa tråddragningen till basen. Huvudenheten ansluts a. Instalację sygnalizatora nale y zacząć od monta u podstawy w sedan automatiskt när den monteras på basen. odpowiednim miejscu i podłączenia jej do instalacji zewnętrznej.
  • Página 7 Installationsanvisninge Installation a. Lydalarmen installeres ved først at montere bunden samt trække de udvendige ledninger til bunden. Hovedet tilsluttes derefter automatisk, når det fastgøres til bunden. b. Hovedet på lydalarmen skilles fra bunden ved at løsne de fire låseskruer i hvert hjørne af lydalarmen.

Tabla de contenido