GENERAL DESCRIPTION
The photocell FOTO30SDE has been designed and created for use on power operated doors (gates, doors,..). It has autotest function,
usable with control units able to manage it (e.g. EURO1MF or EURO2MF). The autotest function is carried out as follows: before any
manoeuvre the station inhibits the transmitter by sending a voltage between +5 and +24 V dc on terminal N° 3. The absence of the
infrared beam thus brought about generates, with a 20 ms. delay, opening of the receiver's N.C. contact. The station checks that the
described procedure is properly carried out before each manoeuvre. It complies with european directive 98/336/EEC (EMC).
2.
APPLICATIONS
With stations equipped with autotest device for safety applications.
3.
MAIN TECHNICAL FEATURES
Power supply (TX - RX)
Rest/Work Consumption
Container
Size / Weight
modulation frequency
Degree of insulation
Infrared wavelength
Relay contact capacity
Infrared beam range
Working temperature
Intervention time
4.
RECEIVER TERMINAL BOARD
1
+12 ÷ +24 V ac/dc
2
0 V
3
N.C.
4
C
5
N.A.
5.
TRANSMITTER TERMINAL BOARD
1
+12 ÷ +24 V ac/dc
2
0 V
3
Autotest input
6.
FUNCTIONING
Align the beam with the receiver using the relevant adjustment screws "A" (fig. 2) on the receiver and transmitter. Interruption of the
infrared beam generates opening of the normally closed contact of the relay on the receiver and the turning off of the red LED.
7.
NOTES
Alignment is checked by voltmeter measuring of tension at the receiver test-point (fig.3). This value varies in accordance with various
parameters, among which the distance between the photocells. The higher the voltage value at the test-point, the better the alignment.
This value can range between 0 and 5 Vdc.Optimun voltage should be between 0,5 and 0,6 Vdc.
ENGLISH
12 ÷ 24 V ac/dc
50 mA (TX+RX)
ABS
110 x 50 x 25 mm 200g
1000 Hz
IP 45
950 nm
0,5 A @ 24 V ac/dc
30m nominal ( 8m in external use )
-20 +70° C
< 20ms
Power supply 12 - 24 V ac/dc
Common supply
Relay contact normally closed
Common relay contact
Relay contact normally open
Power supply 12 - 24 V ac/dc
Common supply
From +5 to +24 Vdc to block infrared beam emission