Uline H-7096 Manual Del Usuario

Uline H-7096 Manual Del Usuario

Ventilador de pared para uso pesado - fijo
Ocultar thumbs Ver también para H-7096:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

H-7096, H-7097
HEAVY-DUTY WALL MOUNT
FAN – STATIONARY
CAUTION! Read all instructions carefully before
attempting to assemble, install, operate or
service the product. Failure to comply with
instructions could result in personal injury
and/or property damage. Using this product
for any other purpose than it was intended, or
not within the operating specifications in these
instructions will void the warranty and may
cause damage to the fan or serious injury to
personnel.
WARNING! To reduce risk of fire, electric shock
or personal injury:
• This fan is intended for general use only.
Do not use near hazardous or explosive
materials or vapors.
• Before operating this fan, check for worn,
damaged or missing parts and replace or
repair as needed.
• Disconnect from power source before
servicing.
• Never insert fingers or any other objects
through the guards when fan is in operation.
• Never operate fan without guards in place.
• Certain fans have guards that are not OSHA
compliant. These units are designed to
be intrinsically safe; however, never allow
children near fan when in operation. Uline
recommends these fans be installed greater
than 7' from the ground.
• Unplug the fan before moving from one
location to another.
PAGE 1 OF 12
1-800-295-5510
uline.com
SAFETY
• Fan must be located in an area that allows
for adequate airflow around the fan. Starving
the fan of air may cause motor to overheat
and trigger the unit to shut off.
• Fan motor is thermally protected and will
shut off if overheated. Turn unit off and allow
motor to cool before restarting.
• Carefully read all safety messages in these
instructions and on equipment safety labels.
• Warning labels must be kept in good
condition and be replaced if necessary.
• Follow recommended precautions and safe
operating practices.
• Suitable for damp locations; GFCI is required.
• Do not use this fan with any speed control
device unless otherwise noted.
Para Español, vea páginas 5-8.
Pour le français, consulter les pages 9-12.
0821 IH-7096

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Uline H-7096

  • Página 1 • Certain fans have guards that are not OSHA compliant. These units are designed to be intrinsically safe; however, never allow children near fan when in operation. Uline recommends these fans be installed greater than 7' from the ground. • Unplug the fan before moving from one location to another.
  • Página 2: Mounting Hardware

    Hardware must be adequately sized and be the proper type for installation to Contact Uline Customer Service at 1-800-295-5510 safely support the fan. Always follow the fastener immediately if any damage is found.
  • Página 3 INSTRUCTIONS CONTINUED ATTACHING FAN TO MOUNT REMOVING MOTOR DRAIN PLUGS After installing the fan, remove the motor drain plug Use the supplied hardware to attach fan to the mount. The 3/8" bolt installs through the center hole of the located at the lowest point of the motor. motor yoke bracket.
  • Página 4 Repair or replace motor. Loose guards. Tighten guard fasteners. Excessive vibration. Damaged fan blade. Replace fan blade. Motor shaft is bent. Repair or replace motor. Motor is loose. Realign if necessary and tighten fasteners. 1-800-295-5510 uline.com PAGE 4 OF 12 0821 IH-7096...
  • Página 5: Ventilador De Pared Para Uso Pesado - Fijo

    Uline recomienda que estos ventiladores se instalen a más de 2.1 m (7') del suelo. PAGE 5 OF 12...
  • Página 6: Continuación De Seguridad

    Si encuentra daños comuníquese de inmediato a que la instalación sostenga el ventilador de manera Servicio a Clientes de Uline al 800-295-5510. segura. Siga siempre las instrucciones del fabricante del sujetador de instalación.
  • Página 7: Continuación De Instrucciones

    CONTINUACIÓN DE INSTRUCCIONES FIJAR EL VENTILADOR AL SOPORTE REMOVER TAPONES DE DESAGÜE DEL MOTOR Después de instalar el ventilador, retire el tapón de Use la tornillería suministrada para fijar el ventilador al soporte. El perno de 3/8" se instala a través del orificio desagüe del motor ubicado en el punto más bajo del motor.
  • Página 8: Mantenimiento

    Aspas del ventilador dañadas. Reemplace las aspas del ventilador. El eje de motor está doblado. Repare o reemplace el motor. Motor flojo. Vuelva a alinear si fuera necesario y apriete los sujetadores. 800-295-5510 uline.mx PAGE 8 OF 12 0821 IH-7096...
  • Página 9 MISE EN GARDE! Lisez attentivement toutes les ventilateur lorsque celui-ci est en marche. instructions avant de procéder au montage, Uline recommande pour ces ventilateurs une à l'installation, à l'utilisation ou au maintien installation à une hauteur supérieure à 2.1 m de l'article.
  • Página 10 Il incombe à l'utilisateur de déterminer si la Contactez immédiatement le service à la clientèle structure est adéquate pour pouvoir supporter de Uline au 1 800 295-5510 si vous constatez un cette charge. quelconque dommage. PAGE 10 OF 12...
  • Página 11 INSTRUCTIONS SUITE MATÉRIEL DE FIXATION CÂBLE DE SÉCURITÉ Le matériel requis pour pouvoir fixer le support de Un câble de support secondaire (non inclus) doit être ventilateur à la structure de soutien n'est pas fourni. installé chaque fois que le ventilateur est monté en Le matériel de fixation doit présenter des dimensions hauteur pour plus de sécurité.
  • Página 12: Dépannage

    Pale de ventilateur Remplacez la pale du ventilateur. endommagée. Réparez ou remplacez le moteur. L'axe du moteur est tordu. Réalignez si nécessaire et serrez Le moteur est desserré. le matériel de fixation. 1-800-295-5510 uline.ca PAGE 12 OF 12 0821 IH-7096...

Este manual también es adecuado para:

H-7097

Tabla de contenido