Xavax Selina Instrucciones De Uso página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
g Operating Instructions
BATTERY
Type 1.
1x3V lithium battery (CR2032).
Please remove the isolation sheet from the battery contact before use.
TO REPLACE BATTERY
Contact
Condition 1:
Black tab
Open battery case cover on the back of scale, if battery case is the type shown in picture 1,
A. Bend the small black tab outwards and the battery will come out. Take note not to bend the contact.
B. Install new battery by putting one side of the battery beneath the contact and then pressing
down the other side.
Picture 1
Condition 2:
Open battery case cover on the back of scale, if battery case is the type shown in picture 2,
A. Take out the used battery with the aid of a sharp object, as shown in picture 2.
B. Install new battery by putting one side of the battery beneath the battery baffle and then pressing
down the other side.
Battery baffle
Picture 2
OPERATION
STEP 1.
Put the scale on a hard & flat surface (avoid carpet or soft surface).
STEP 2.
Gently step on the scale, then the scale will be automatically turned on. Stand evenly until on
the scale without moving and wait until your weight shown on display is stable and locked.
AUTOMATIC SWITCH OFF
When you step off the scale, it will automatically switch off. Auto shut-off occurs if display
shows "0.0" or show the same weight reading for approximate 8 seconds.
4
TO CONVERT WEIGHT UNIT
If the scale is with both measuring system of Metric (kilograms) and Imperial (pounds, stones), you can convert weight unit as
following:
Condition 1:
if the unit switch is inside battery case,
A. Open battery case cover on the back of scale.
B. Pull up and down the unit switch to convert scale unit between kg-lb-st.
Unit switch
Condition 2:
Battery
if the unit switch is on the back of the scale,
Cover
A. Find unit switch on the back of scale.
B. Pull up and down the unit switch to convert scale unit between kg-lb-st.
Unit switch
OVERLOAD INDICATION
Scale overload. (max. weight capacity is indicated on the scale).
Please step off to avoid damage.
LOW BATTERY INDICATION
Battery power is low. Please install new battery.
RE-TEST
Display "
" when you step off the scale, means this weight reading with error. Please re-test.
ADVISE FOR USE & CARE
1. The glass platform will be slippery when it is wet. Keep it dry!
2. Keep standing still during the course of weighing.
3. DO NOT strike, shock or drop the scale.
4. Treat the scale with care as it is a precise instrument.
5. Clean the scale with a damp cloth and avoid water getting inside the scale. DO NOT use chemical/abrasive cleaning agents.
6. Keep the scale in cool place with dry air.
7. Always keep your scale in horizontal position.
8. If failed to turn on the scale, check whether battery is installed, or battery power is low. Insert or replace new battery.
9. If there is error on display or cannot turn off the scale for a long time, please take off the battery for about 3 seconds, then install it
again to remove soft-fault. If you cannot resolve the problem, please contact your dealer for consultation.
10. Do not use it for commercial purpose.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido