Installation Instruction; Overview; Technical Specifications; Dimensions - clage DBX 18 Next Instrucciones De Uso

Ocultar thumbs Ver también para DBX 18 Next:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
DBX Next

Installation instruction

1. Overview

See figure C1.
EN
Pos.
Function
1
Bottom part
2
Safety thermal cut-out (STB)
3
Thermal sensor set
4
Heating element
5
Non-return valve
6
Flow sensor
Safety pressure cut-out SDB
7
8
Outlet pipe
9
Flow limiter
10
Hot water connection
11
Screw-in nipples ½ inch
12
Grommet

2. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
Electrical connection
Min. required cable size
1)
Hot water (l/min)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required specific water resistance
Specific electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
VDE class of protection
Type of protection / safety
* ) The declaration complies with the EU regulation No 812/2013
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Flow rate limited to achieve optimum temperature rise
4) Without flow regulator

3. Dimensions

Dimensions in mm (fig. D1)
DBX 18 Next
18 kW / 26 A
4.0 mm
9.2
2)
6.8
1.5 l/min – 7.0
2
at electrical connection from above
Pos.
Function
Water splash protection sleeve
13
Wall bracket
14
DBX Next hood
15
Connecting pipe
16
PCB cover
17
PCB
18
Connecting terminal
19
20
Control panel with bracket
Inlet pipe
21
Fine filter
22
Cold water connection
23
Frame
24
DBX 21 Next
A *
)
21 kW / 30 A
3~ / PE 380..415 V AC
4.0 mm
2
10.7
7.9
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1100 Ωcm
≤ 90 mS/m
≤ 30 °C
3)
1.5 l/min – 8.0
0.08 bar at 1.5 l/min 1.3 bar at 9.0 l/min
30 °C – 60 °C
G ½ inch
4.2 kg
I
9
DBX 24 Next
24 kW / 35 A
6.0 mm
2
12.3
2)
9.0
®
3)
1.5 l/min – 8.0
4)
IP25
2
2)
2)
3)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dbx 21 nextDbx 24 next

Tabla de contenido