Types of timers - TYPES DE TEMPORISATEUR - TIPOS DE TEMPORIZADOR
1 - Pushbutton Monostable (Equivalent I - 1/2/3)
STAR button to close the relay is energized and remain energized until time is up.
2 - Monostable voltage (equivalent I - 1/2/3)
When the power relay is energized and remain energized until time is up.
3 - Push-pausable Monastery
START button to close the relay is energized and remain energized until the end of the time If closed during timing and holding down the START button,
time pauses. When you open the START continuous timing.
4 - Push-resettable monostable
Closing the START push button activates the relay, staying on until time is up. If during the timing START button closes the relay releases
5 - Monostable switch contacts open
By closing the switch ignores the timer START, START button to open the relay is activated and remain activated until time is up .
6 - Push-retriggerable monostable (Equivalent I - 30/31)
START button to close the relay is energized and remain energized until time is up. If during the timing is closes the START button is reset and begins
timing time again
7 - Pushbutton Monostable cumulative
START button to close the relay is energized and remain energized until time is up. If during the timing is START button closes builds another time
period.
8 - Delay start-up voltage (Equivalent R 36/37)
When the power starts without connecting the timing relay. When time is connected to the relay, it is fixed to turn off the power.
9 - Delay start launched by button (Equivalent R 36/37)
Closing the STAR button starts the timer without connecting the relay. When time is connected to the relay, it is fixed to disconnect power
10 - Delay start button retriggerable by
Closing the START button starts the timer without connecting the relay. If timing is closed during the START button resets the timer and start the time
again. When time is connected to the relay, it is fixed to Food disconnect.
11 - Delay start button accumulative
Closing the START button starts the timer without connecting the relay. If the timing for closing the START button builds another time period. When time
is connected to the relay, it is fixed to disconnect the feeding.
12 - Push-delayed activity (Equivalent I – 38/39)
Closing the START button activates the relay but without timer, open the START button starts the timer stays on until time is up.
13 - Push-retriggerable delayed action
Closing the START button is activated but without a timer relay, opening the button starts the timer stays on until time is up. If timing is closed during the
START button resets the timer and start the time again.