Preliminary Checks - ulixes 350 Instrucciones

Motorreductor electromecánico para portones de batiente
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Preliminary checks

Check the following points before commencing to install Ulixes:
Check that the gate structure is sufficiently robust and there are no points of friction.
Check the condition of the gate hinges; make sure they are adequately lubricated.
Check there is a mechanical stop in closing.
Check value "C" before installing, observing the specifications in the assembly table (Tab.1, Tab. 2).
By increasing value "B" the opening angle is reduced, peripheral speed and the thrust of the motor on
the gate is increased; to the contrary, by increasing "A" the opening angle is increased, peripheral speed
and the thrust of the motor on the gate is reduced.
Tab. 1
OPENING
Travel 350
90°
90°
Travel 350
90°
Travel 350
Travel 350
90°
Travel 350
115°
Travel 350
115°
Istruzioni , Instructions, Betriebsanleitung, , Instrucciones
A
D
Opening
A
B
C
D
90
143
60
550
90
140
40
550
90
120
20
550
90
100
0
550
120
83
20
530
120
83
0
530
Tab. 2
OPENING
Travel 500
90°
Travel 500
90°
Travel 500
115°
Travel 500
115°
A
A
B
C
D
130
143
60
600
130
140
40
600
150
103
20
600
150
100
0
600