OPERATION
Pilot flame ignition
Start from the "OFF" position. Rotate the control
knob to the "PILOT" position. Press the knob
and light the pilot flame, keeping the knob fully
depressed for thirty (30) seconds or more, until
a strong pilot flame is present. Release the knob
and verify that the pilot flame remains lit.
Igniting the main burner
Turn the control knob to the desired temperature
setting. In the modulating version, the gas
path to the main burner opens when the
ambient temperature is lower than the set point
temperature. In the manual version, the gas
path to the main burner opens immediately when
the knob is rotated to a temperature setting.
Stand-by position
To maintain a flame at the pilot burner with the
main burner off, turn the control knob to the
"PILOT" position.
Turning off
Turn the control knob to the "OFF" position.
CAUTION
After shutting down, wait at least five minutes before re-igniting. This will allow the safety
interlock to reset.

FINAL CHECKS

WARNING:
Fire or Explosion hazard.
Can cause damage to property and severe injury or death.
Do not force the control knob. Use only your hand to turn the knob. If the knob does not move

by hand, the valve should be replaced by a trained service technician.