Empty the complete contents of the required number of bottles of JBL FilterStart over
both of the pre-filter media in the combi filter basket.
Number of bottles of JBL FilterStart:
Put the pump head back on the filter canister and close the locking clips.
Please note: The empty filter baskets are interchangeable (excepting e401). However, the
combi filter basket is the only one that can be inserted last on top. The pump head can be
turned 180° in any direction.
Tip: Always open and close clips positioned opposite each other. This prevents unnecessary
wear on the pump head seal and ensures an accurate fit when the filter canister is closed.
2
Attaching the hose connection block and hoses
Turn the two small stopcock levers on the pump head to the ( ) position opposite the
"OPEN" mark, so that the groove in the base of the levers points vertically upwards.
Place the hose connection block with the middle lever pointing upwards into the pump
head and press it down firmly.
To fasten, press the middle lever down to secure and turn the two small stopcock levers to the
"OPEN" position. Now the ball valves integrated in the hose connection block are open and
the hose connection block cannot be removed, even if the middle lever is raised (safety lock).
Push each hose onto a hose connection and turn the nut anti-clockwise until the hose fits
firmly.
3
Positioning the filter
The filter can now be positioned in the intended place for use in the aquarium cabinet or
similar. attention must be paid to the following: If the filter is to be housed in the cabinet,
the distance in height between the surface of the water and the bottom of the filter may not
exceed 180 cm max. (max. 120 cm for the e401 ). If the filter is located next to the aquarium,
the distance between the surface of the water and the top of the filter must be at least 20 cm.
CAUTION: the filter should always be operated in an upright position!
4
Attaching pipes and hoses
Place the intake strainer on the end of the suction pipe and attach it to the inside of the
aquarium using the suction cups and pipe clips. Use long or short clips depending on the
design of the aquarium edge. Pull out the telescopic pipe so that the intake strainer is
about 5 cm above the base of the aquarium. The two parts of the telescopic pipe are sealed
against one another by an O-ring so that no air is drawn into the telescopic pipe, even if the
13_60210_00_0_V04.indd 21
CristalProfi e401:
1 bottle
CristalProfi e701:
1 bottle
CristalProfi e901:
2 bottles
CristalProfi e1501:
3 bottles
CristalProfi e1901:
4 bottles