2.TECHNICAL FEATURES
Internal selection of the range by removable straps and fine settings by
multi-turn potentiometers. (see configuration of inputs p5)
Voltage
±10 mV / ±100 mV
±1 V / ±10 V / ±100 V / ±500 V
Current
±5 mA / ±50 mA
Integrated supply for 2-wire sensors 22V ±20% (I max. : 25 mA)
Possibility to achieve shifted scales.
Current
0-20mA, 4/20mA,
±20mA
Voltage
0-10 V,
bidirectionnal
±10 V,
20 to 270 Vac 50/60/400Hz and 20 to 300 Vdc
on load
Power Draw
empty
: ≤ 0.2
Accuracy rating
Undulation
: ≤ 0.5%
Galvanic partition
: input / output / power supply
2 kV eff. 50Hz 1min.
TMP-HI (4kV eff. 50Hz - 1 min.)
Response time
: ≤ 250ms [Tr]
Pass-band
: 1.5 Hz (-3 decibels) [Bp = 0.35/Tr]
: ≤ 0.015%/°C
Temperature Coeff.
Shifted or inverted scales.
Passive current output : 0/20mA, 4/20mA
Short response time : > 10 ms
Long response time : < 30 s
DC
DC
Rc* < 750Ω
Rc* < 320Ω
Rc* > 1KΩ
Rc* > 1KΩ
: < 4.5 VA (2,5W)
: < 2.5 VA (1W)
U : 30V max.
p3
3.EXTERNAL FEATURES
A3 A2 A1
S4 S3 S2 S1
>
>
x
120
22.5
E5 E6 E1 E2 E3 E4
4.CONNECTIONS
I
nputs
E1 E2 E3 E4
U ≥ 1V
V
U < 1V
V
I ≤ 50mA
mA
2-wire sensor
+
-
O
utputs
Voltage and
current, active
S1 S2
0-4/20mA
mA
+
-
active
0-10V
V
+
-
Dimensions :
(H x L x D)
75 x 22.5 x 120 mm
(H=108, with terminals)
Weight
: 130g
75
Protection
: Case/terminals : IP 20
Case :
Sel-extinguishing in black ABS UL94VO
Latching on symmetrical DIN rail.
Plug-in connectors for screwed con-
nections (2.5mm², flexible or rigid)
S
upply
A1 A2 A3
E5 E6
mA
~
~
AC
DC+
-
I > 50 mA
Option passive
current output
S2 S3
+
Lr
-
0-4/20mA passive
external source 30 V max.
p4