Amprobe IRC-110 Manual Del Usuario página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Image resolution
Field of view
Thermal sensitivity
Focus system
Image palettes
Hot and cold marker
Display
Operating temperature
and humidity
Storage temperature
Visual to IR effective image
alignment
Operating and storage
altitude
Drop proof
Vibration and shock
Power supply
Battery life
Auto power off
Agency approvals
Electromagnetic
Compatibility
Size (H x W x L)
Weight
16,384 pixels (128 x 128 pixels)
(Interpolation pixels)
33 ° x 33 °
150 mK
Focus free
Grayscale (white hot), Hot Iron and Rainbow
Yes
1.77 in color TFT with 128 x 160 pixels
32 °F to 122 °F (0 °C to 50 °C)
10 % to 90 % RH non-condensing at 86 °F
(30 °C)
-4 °F to 140 °F (-20 °C to 60 °C) without
batteries
≥ 10 inches (25.4 cm), optimal of 1 meter
< 6561 ft (< 2000 m)
4-feet (1.2 m)
IEC 60068-2-6, 2.5g, 10 to 200 Hz, IEC 60068-2-
27, 50g 11ms
Three (3) 1.5 V AA IEC LR6 alkaline batteries
8 hours with display ON (Typical)
Power consumption: 150 mA (Typical)
Selectable modes: OFF, 1 minute, 2 minutes, 5
minutes and 10 minutes
P
EN 61326-1
Korea (KCC): Class A Equipment (Industrial
Broadcasting & Communication Equipment)
[1]
This product meets requirements for
industrial (Class A) electromagnetic wave
equipment and the seller or user should take
notice of it. This equipment is intended for
use in business environments and is not to be
used in homes.
Approx. 7.3 x 2.1 x 4.1 in (185 x 54 x 104 mm)
Approx. 0.57 lb (0.26 kg)
11
[1]

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Irc-110-cn

Tabla de contenido