Where water is supplied at a higher flow rate, than the working
flow rate of the injector or where the injector isn't needed for
continuous operation, the MixRite must be installed on a bypass line.
The bypass provides the possibility to close the operation of the
injector while water continues to flow through the line.
1. Install onto the water line using swivel connectors and ensure
2. Install a 50-75 mesh (250-300 micron) filter between the valve
3. Valves have to be installed at the bypass entry and exit and on
4. Position the liquid additive container beneath the injector. Check
I-870
Rev F - 36742
Installing the MixRite on a Bypass line (o line)
that the water flows into the MixRite in the direction indicated by
the arrows printed on the MixRite.
and the injector intake.
the main water line.
to ensure that the suction pipe is not bent or folded. Position the
drawing pipe into the additive container. Ensure that the suction
pipe filter is set several millimeters above the container's bottom.
Install the MixRite on Bypass Line (O Line)
Page 5 of 30