A MixRite Bypass installation
2.5 (M/h)
including mobile fertilizer solution
tank
Chocking valve
Operating valve
Every stroke of the MixRite moves a predetermined volume of
water with a predetermined volume of liquid additive.
To adjust the volume of the liquid additive in models 570(CW/CL/PVDF),
572(CW/CL/PVDF), 571(CW/CL/PVDF), 573(CW/CL/PVDF), 576IN,
578IN, 577IN, 579IN:
1. Remove the upper U–latch from the Proportioning Lock Nut.
2. Preset the amount of additives according to the Percentage to
• Turn the proportioning Adjuster counter clock-wise to increase
• Turn the Proportioning Adjuster clock-wise to decrease the
3. Turn the proportioning Adjuster slightly, until the U-latch holes of
4. Push the U-latch into the U-latch holes of Proportioning Lock Nut
I-870
Rev F - 36742
Adjusting the MixRite
Water Scale that is found on the proportioner.
the amount of additives.
amount of additives.
The marking on the scale indicates the % of additive out of
the total water flowing through the injector.
the Proportioning Lock Nut align with the notches in the
proportioner.
until it is firmly in place.
Main Water Pipe
Reservior Tank
Page 6 of 30