Product Features - Bosch GRL 400 H Professional Manual Original

Ocultar thumbs Ver también para GRL 400 H Professional:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
OBJ_BUCH-1179-001.book Page 20 Thursday, August 5, 2010 10:04 AM
20 | English
Battery Charger
Article number
Rated voltage
Frequency
Output voltage
Charging current
Allowable charging temperature range
Charging time
Number of battery cells
Rated voltage (Rechargeable batteries)
Weight according to EPTA-Procedure 01/2003
Protection class

Product Features

The numbering of the product features refers to
the illustration of the rotational laser level and
battery charger on the graphics page.
1 Automatic levelling indicator
2 On/Off button / shock-warning button
3 Shock-warning indicator
4 Variable laser beam
5 Exit opening for laser beam
6 Charge-control indicator
7 Battery pack
8 Battery compartment
9 Locking knob of the battery compartment
10 Locking knob of the battery pack
11 Socket for charge plug
12 Tripod mount 5/8"
13 Serial number
14 Laser warning label
15 Battery charger
16 Mains plug of the battery charger
17 Charge connector
18 Tripod*
19 Construction laser measuring rod*
20 Laser receiver*
21 Laser viewing glasses*
22 Measuring plate with stand*
23 Holder*
24 Case
* The accessories illustrated or described are not in-
cluded as standard delivery.
2 610 A13 330 | (5.8.10)
V~
Hz
V=
A
°C
h
V=
kg
Assembly
Power Supply of the Rotational Laser
Level
Operation with Batteries/Rechargeable
Batteries
Using alkali-manganese or rechargeable batter-
ies is recommended for operation of the meas-
uring tool.
To open the battery compartment 8, turn the
locking knob 9 to position
battery compartment.
When inserting batteries, pay attention to the
correct polarity according to the representation
on the inside of the battery compartment.
Always replace all batteries at the same time.
Only use batteries from one brand and with the
identical capacity.
Shut the battery compartment 8 and turn the
locking knob 9 to the
position.
In case the batteries have been inserted incor-
rectly, the measuring tool cannot be switched
on. Insert the batteries with correct polarity.
Remove the batteries from the measuring
tool when not using it for extended periods.
When storing for extended periods, the bat-
teries can corrode and discharge themselves.
2 610 A13 782
100–240
50/60
7.5
1.0
0–45
14
2
2 x 1.2
0.2
/II
and pull out the
Bosch Power Tools

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3 601 k61 800

Tabla de contenido