A. Remove bracket base casting by unscrewing outer trilobular fixings, then assuming masonry
wall mounting, mark & drill 4 x Ø7 holes using bracket base casting as pattern, shown above.To
assist with orientation flats are provided on all 4 axes allowing the use of a spirit level for
alignment. (Fig 8) (use goggles when drilling).
B. Insert 4 x M6 Rawlplugs into wall until flush.
C. Offer bracket base casting into position & screw wall fixing screws through into inserts.
D. Tighten fixings to secure. Note: An optional spreader plate (9011) is recommended when fixing
to brickwork to reduce the 'pull out' forces on a single brick.(Available from Dedicated Micros on
request).
Note: Locating a dome on a corner of a building will give an increased area of surveillance. For this application
Dedicated Micros are able to offer an optional corner bracket (9007) to adapt the standard wall bracket.
E. Thread cable from bracket through cable entry hole in bottom of bracket base casting, then fit
the bracket (Fig 9) (Note: bracket base casting can be orientated to position the entry hole to
either side or at the top.).
F. Using supplied trilobular fixings attach bracket to base casting as shown. (Fig 10).
Wall Fixing Screws
Fig. 9
Dennard 2060 Operation Manual
Fig.8 Bracket Base Casting
E
4 x Ø7mm
Outer Trilobular Fixings (M6 x 16)
Fig. 10