Sucking Up Asbestos-Containing Substances; Emptying The Container - SPIT AC 1630 P Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
▶ Empty container (see „7 Emptying the container" ).
NOTE
If the vacuum cleaner is not switched off, the re-start protection
remains effective. The vacuum cleaner is ready for operation only
after the unit has been switched off and switched on again.
▶ Remove the suction hose from the liquid before emptying.
▶ After switching off, a small quantity of water can flow back out of
the hose, as a result of the high suction level and the favourable
flow condition in the container.
▶ After wet vacuum cleaning insert dry filters for picking up dry
dust.
NOTE
When changing frequently between dry and wet vacuum
cleaning, use a second set of filters, preferably polyester folded
filter cartridges.

5.3 Sucking up asbestos-containing substances

Only vacuum cleaners of dust class H-asbestos may be used for
vacuuming asbestos-containing substances.
▶ Only work with a dry filter, vacuum cleaner and accessories to
prevent dust from sticking and becoming incrusted.
▶ For sucking up asbestos-containing substances: Insert the PE
emptying bag or fleece filter bag into the dirt container.
▶ Always use filter bags in conjunction with folded filter cartridges.
NOTE
H-asbestos class vacuum cleaners should be preferably used as
vacuum cleaners for dry dusts.
l WARNING !
Health hazard !
Asbestos fibres in the air.
▶ Supply the work area with sufficient outside air (fresh air).
▶ Guide or clean extracted air in such a way that asbestos
fibres do not get into the breathing air of other persons.
▶ When filtering the extracted air, transport any dust in dust-
tight containers.
▶ Do not decant dust.
If there is a possibility of asbestos fibres becoming free:
▶ Absorb asbestos fibres at the outlet or point of origin.
▶ Then dispose of asbestos fibres in accordance with the state of
the art without any danger to persons or the environment.
If complete absorption of asbestos fibres is not possible:
▶ Take additional ventilation measures in accordance with the
state of the art.
After completion of the work:
▶ Carefully clean tools, including suction tubes and work
equipment.
▶ Carefully clean the working area.
▶ Moisten and properly remove objects contaminated with asbes-
tos fibres that cannot be cleaned.
12
After cleaning:
▶ Ventilate the working area sufficiently.
6
Permanent filter cleaning
The vacuum cleaner is fitted with an electromagnetic filter cleaning
system, which can be used to clean any attached dust from the
filter cartridges.
The folded filter cartridges are cleaned alternately one after the
other so that continuous work is guaranteed.
7

Emptying the container

NOTE
Only permitted for dust with workplace exposure limits > 1 mg/m³.
▶ Switch off the vacuum cleaner, pull out the mains plug.
▶ Open the latches.
▶ Remove the cover and suction hose from the container.
▶ Empty the container by pouring out.
7.1 Dispose of the fleece filter bag
▶ Switch off vacuum cleaner.
▶ Disconnect mains plug.
▶ Wear appropriate breathing mask.
▶ Remove suction hose.
▶ Close off intake socket with cap.
▶ Open side latches.
▶ Remove top section.
▶ Carefully pull the flange off the intake socket and close off the
flange.
▶ Dispose of gathered material in accordance with legal require-
ments.
7.2 Dispose of the PE emptying and disposal
bag
▶ Set switch to position >AC<.
↳ Folded filter cartridges are cleaned automatically.
↳ Residual dust in the filters falls into the bag.
▶ Switch off vacuum cleaner.
▶ Disconnect mains plug.
▶ Wear appropriate breathing mask.
▶ Remove suction hose.
▶ Close off intake socket with cap.
▶ Open side latches.
▶ Carefully close the PE emptying and disposal bag with the
enclosed sealing tape.
▶ Carefully pull the flange off the intake socket and close off the
flange.

Publicidad