English
INSTaLLaTION INSTRUcTIONS
Water Supply
Recommended
Maximum
Hot Water Temperature
65 C° (~150F)
80 C° (~175F)
Working Pressure
3 BAR (~45PSI)
5 BAR (~75PSI)
In case of pressures over 5 BAR (~75 PSI), we
screw (4.E), then tighten the latter. Warning! Do
recommend to use a pressure reducer.
not force the screw (4.E). Excessive tightening
Before proceeding with the assembly, purge the
can affect the correct function of the system
hot and cold water pipes so as to avoid the
or damage it. The thermostatic cartridge is
accumulation of dirt and impurities that could
equipped with a safety anti-scalding retainer set
affect the function of the faucet.
at 100°F (38°C). For higher temperatures push
the button on the adjustment handle. In case of
FIG. 01
hot or cold water pressure failure, the flow will
Remove the protection covers (1.A) using a
automatically stop. With a screwdriver loosen
screwdriver. Use the plug (1.B) if necessary.
the stop cocks (4.F) in anti-clockwise direction.
FIG. 02
FIG. 05
Fit the faucet body (2.A) to the wall with the
Remove the protection tape of the adhesive
two upper outlets pointing towards the flow
sponge (5.D) and apply it on the back of the
elements. Connect the hot water supply to the
plate (5.C).
left inlet and the cold water supply to the right
Fit the sliding flat washers (5.B) and (5.A) on
one.
the plate (5.C) and install it on the thermostatic
body till it is flush to the wall.
FIG. 03
The depth of the wall niche must correspond
FIG. 06
(wall coating included) to the tolerance given
Control handles installation.
by the MIN/MAX references given on the
For the upper portion with the stop cock, follow
plastic cover (3.A).
the instructions given below:
Once all connections have been carried out,
Install the protection cover (6.N) on the screw
activate the faucet at the working pressure
down and fit the spacer (6.M) on the screw
(we recommend maintaining the water flow
down bar. Position the handle (6.L) and lock
for a few minutes so as to purge the system
it with the screw (6.H) placing the spacer (6.I)
from any debris and/or dirt inside the piping).
in between. Complete by fitting the cap (6.G).
Temporarily remove the protection cover (3.A)
to check if there are leakages and if the system
For the lower portion with the thermostatic
works regularly, reinstall the protection cover
cartridge, follow the instructions given below:
(3.A) and finish the external wall surface.
install the lever (6.E) placing the spacer (6.F)
on the thermostatic cartridge without moving the
FIG. 04
rod so as to not compromise the calibration of
Remove the protection cover (3.A) as shown
the cartridge. Assemble the handle (6.D), fasten
in FIG. 03. With a screwdriver fasten the stop
it with the screw (6.B) inserting the washer (6.C)
cocks (4.F) in clockwise direction, loosen the
and fit the finishing cap (6.A).
fitting screw (4.E) using the proper wrench
and pull out the test plug (4.D). Insert the o-ring
FIG. 07
(4.C) and the sleeve (4.B) on the thermostatic
To replace only the handle (7.L) follow the
body. Use a small quantity of the special grease
instructions given below:
included to lightly lubricate the o-rings of the
Remove the cap (7.G), loosen the screw (7.H)
thermostatic cartridge (4.A). Insert the cartridge
and pull out the handle (7.L) with the spacer
in the faucet housing carefully aligning the
(7.I).
positioning hole with the housing of the fitting
Install the new handle (7.L) and fasten it using
Istruz. art. 8869100.indd 4-6
fIG. 01
Minimum
15 C° (~60F)
0.5 BAR (~7PSI)
fIG. 03
fIG. 05
fIG. 02
fIG. 07
fIG. 04
fIG. 08
fIG. 06
fIG. 09
26/04/11 09:59