INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION ET DE MAINTENANCE
INBETRIEBNAHME - UND WARTUNGSANLEITUNG
INSTRUCCIONES DE PUESTA EN MARCHA Y MANTENIMIENTO
INSTRUZIONI DI MESSA IN SERVIZIO E MANUTENZIONE
ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES
INSTALLASJONS- OG VEDLIKEHOLDSINSTRUKSER
INSTALLATIONS- OCH UNDERHÅLLSINSTRUKTIONER
ASENNUS - JA HUOLTO-OHJEET
INSTALLATIONS - OG VEDLIGEHOLDSANVISNINGER
INSTRUÇÕES DE INSTALAÇÃO E MANUTENÇÃO
ΟΔΗΓΙΕΣ ΤΟΠΟΘΕΤΗΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ
POKYNY PRO INSTALACI A ÚDRŽBU
INSTRUKCJA MONTAŻU I KONSERWACJI
TELEPÍTÉSI ÉS KARBANTARTÁSI ÚTMUTATÓ
ИНСТРУКЦИЯ ПО УСТАНОВКЕ И ОБСЛУЖИВАНИЮ
ОРНАТУ ЖƏНЕ ҚЫЗМЕТ КӨРСЕТУ НҰСҚАУЛАР
651 - 652 - 653
q
NON ATEX VERSIONS
1/8-1/4 (651) 1/4-3/8-1/2 (652)
ATEX
1/2-3/4-1 (653)
2
EN
FR
DE
651- 652 - 653
ES
IT
NL
NO
SE
NON-ATEX VERSIONS
q
652 SERIES
USABLE IN ATEX ZONES
FI
This product category does not require certification. There is no potential ignition risk to the products themselves.
These product categories are named simple mechanical products and do not include moving parts. These products
can be used in specific explosion zones 1 and 21 in compliance with our installation instructions:
• Mounting components
• Assembly and connection components
• Mechanical accessories
4..20
• Filter and coalescing filter
• Lubricator
• Diverter block
• Shut-off valve
These conditioning units of compressed air and their accessories are envisaged for use in explosive atmos-
pheres in the form of gas, steam, mists and dust.
______________________________________________________________________________________________
DK
!
SPECIAL CONDITIONS FOR SAFE "X" USAGE :
Risk from electrostatic charges
Prevent electrostatic charging of external insulating surfaces by using the appropriate installation and cleaning
measures. To clean external insulating surfaces use a damp cloth.
Connect the conditioning units to the earth.
When combined with other conditioning units, ensure that all metallic and conductive parts are always intercon-
nected and linked to the earth to avoid significant electrostatic charges being created.
The earth is connected to the unit or to the combination of conditioning units by the downstream and upstream
use of metal pipes connected to the earth. If the pipes are non-conductive, earth connection should be performed
by the assembly and/or fixing devices adapted to the ATEX products.
______________________________________________________________________________________________
Installation, commissioning and servicing and maintenance
These operations may only be carried out by authorised personnel and in accordance with the usage instructions.
EN
PT
If during maintenance it is established that wearing and spare parts need exchanging, contact an ASCO
Only carry out maintenance in zones where there is no explosive atmosphere.
Numatics reseller.
Any modification of the product with parts not supplied by the manufacturer will invalidate the certification.
Filtre et Lubrificateur équipés de cuve métallique : (Voir fig. A)
Lors d'un remplacement d'élément filtrant saturé du Filtre, procéder comme décrit ci-dessous :
• Enlever la cuve (2) du corps (3)
• Dévisser la vis (1)
• Retirer l'élément filtrant et le remplacer par un neuf
• Remettre la cuve (2) en place
• Revisser la vis (1) dans le corps (3) jusqu'au contact de la cuve et effectuer ¼ à ½ tour supplémentaire pour
assurer la continuité de masse.
Pour ajouter de l'huile dans la cuve du Lubrificateur, procéder de la même façon que ci-dessus
GR
3
516025-001
CZ
PL
HU
RU
KZ
3
516681-001
651 + 652 + 653 Series
metal
fi g. A
polycarbonate
3
q
1
2
516681-001